Remote control commands
R&S
®
RTB2000
354
User Manual 1333.1611.02 ─ 11
Manual operation:
See
"[Offset/Position (upper knob)]"
REFCurve<m>:VERTical:SCALe
<Scale>
Changes the vertical scale of the reference waveform.
Suffix:
<m>
.
1..4
Selects the reference waveform.
Parameters:
<Scale>
Default unit: V/div
Manual operation:
See
REFCurve<m>:WCOLor
<WaveformColor>
Selects a color for the reference waveform. The default color is white. You can select
another monochrome color, or a color scale.
Suffix:
<m>
.
1..4
Selects the reference waveform.
Parameters:
<WaveformColor>
YELLow | GREen | ORANge | BLUE | LBLUE | WHITE | CYAN |
PINK | RED | TEMPerature | RAINbow | FIRE | DEFault
*RST:
DEF
Manual operation:
See
REFCurve<m>:LABel
<WaveformLabel>
Defines a label for the indicated reference waveform.
Suffix:
<m>
.
1..4
Selects the reference waveform.
Parameters:
<WaveformLabel>
String parameter
String parameter
Example:
REFCurve2:LABel "Origin"
Sets the label "Origin" for reference R2.
Manual operation:
See
Waveform analysis