Waveform analysis
R&S
®
RTB2000
114
User Manual 1333.1611.02 ─ 11
To save the segment table
1. Connect a USB flash drive to the instrument.
2. In the segment table window, tap "Save".
3. To select the target folder, double-tap it.
4. Tap "New File".
5. Enter the filename.
6. Tap "Enter".
The file is saved immediately, and the window is closed.
6.4.5.2
File organization and content
The segment table and history segments are saved to CSV files.
Segment table
The segment table file contains all information that is shown in the table, and also all
timestamps: relative time, time to previous, and absolute time.
Figure 6-8: Content of a segment table file
Waveforms
Each history segment is saved to a separate file, and all segment files are written to a
folder that contains only the files of the saved acquisition. You can specify the name of
the folder. The names of the data files include the segment index.
Figure 6-9: Content of a history waveform folder
History and segmented memory (option R&S
RTB-K15)