Command Reference
R&S
®
CMW-KN5xx
98
User Manual 1176.7690.02 ─ 05
<2_OutOfTol>
Out of tolerance result, i.e. percentage of measurement inter-
vals of the statistic count for modulation measurements exceed-
ing the specified modulation limits.
Range:
0 % to 100 %
Default unit: %
<3_EVM_RMSlow>
<4_EVM_RMShigh>
<5_EVMpeakLow>
<6_EVMpeakHigh>
Error vector magnitude RMS and peak values for low and high
EVM window position
Range:
0 % to 100 %
Default unit: %
<7_MErrRMSlow>
<8_MErrRMShigh>
Magnitude error RMS value for low and high EVM window posi-
tion
Range:
0 % to 100 %
Default unit: %
<9_MErrPeakLow>
<10_MErrPeakHigh>
Magnitude error peak value for low and high EVM window posi-
tion
Range:
-100 % to 100 %
Default unit: %
<11_PErrRMSlow>
<12_PErrRMSh>
Phase error RMS value for low and high EVM window position
Range:
0 deg to 180 deg
Default unit: deg
<13_PErrPeakLow>
<14_PErrPeakHigh>
Phase error peak value for low and high EVM window position
Range:
-180 deg to 180 deg
Default unit: deg
<15_IQOffset>
I/Q origin offset
Range:
-100 dBc to 0 dBc
Default unit: dBc
<16_FreqError>
Carrier frequency error
Range:
-80000 Hz to 80000 Hz
Default unit: Hz
<17_TimingError>
Transmit time error
Range:
-32000 Ts to 32000 Ts
Default unit: Ts (basic LTE time unit)
<18_TXpowerMin>
<19_TXpowerMax>
Minimum and maximum user equipment power
Range:
-100 dBm to 55 dBm
Default unit: dBm
<20_PeakPowMin>
<21_PeakPowMax>
Minimum and maximum user equipment peak power
Range:
-100 dBm to 55 dBm
Default unit: dBm
<22_RSTXpowMin>
<23_RSTXpowMax>
Minimum and maximum RSTX power
Range:
-100 dBm to 55 dBm
Default unit: dBm
Multi Evaluation Measurement Commands