GUI Reference
R&S
®
CMW-KN5xx
43
User Manual 1176.7690.02 ─ 05
When you modify the duplex mode or the channel bandwidth, this parameter is auto-
matically set to the default values defined in 3GPP TS 36.141, see
Remote command:
CONFigure:LTE:MEAS<i>:ENB:MEValuation:SPECtrum:ACLR:ENABle
4.2.5 Trigger Settings
The "Trigger" parameters configure the trigger system for the measurement.
Fig. 4-5: Trigger settings
Trigger Source
Selects the source of the trigger event. Some of the trigger sources require additional
options.
●
Free Run (Fast Sync):
The measurement starts immediately after it is initiated. The R&S
CMW decodes
the signal to derive its slot and frame timing. This procedure is repeated after each
measurement cycle.
If you want to measure a MIMO signal, ensure that the measured antenna trans-
mits the synchronization signals PSS and SSS. Otherwise, the synchronization and
this trigger method will fail.
●
Free Run (No Sync)
:
The measurement starts immediately after it is initiated, without any synchroniza-
tion. This trigger mode can only be used for ACLR and emission mask measure-
ments.
●
IF Power:
The measurement is triggered by the power of the received signal, converted into
an IF signal. The trigger event coincides with the rising or falling edge of the detec-
ted LTE burst.
●
…External…:
Parameters and Settings