GUI Reference
R&S
®
CMW-KN5xx
35
User Manual 1176.7690.02 ─ 05
See also: "Connection Control (Measurements)" in the R&S
CMW user manual, chap-
ter "System Overview"
Fig. 4-1: Signal routing and analyzer settings
.......................................................................................... 35
......................................................................................... 36
..............................................................................................36
Duplex Mode
Selects the duplex mode of the LTE signal: FDD or TDD.
Remote command:
CONFigure:LTE:MEAS<i>:ENB:DMODe
Scenario
This software version supports only a standalone scenario.
Remote command:
ROUTe:LTE:MEAS<i>:ENB:SCENario:SALone
ROUTe:LTE:MEAS<i>:ENB:SCENario?
RF Routing
Selects the input path for the measured RF signal, i.e. the input connector and the RX
module to be used.
Depending on your hardware configuration there may be dependencies between both
parameters. Select the RF connector first. The "Converter" parameter offers only val-
ues compatible with the selected RF connector.
Remote command:
ROUTe:LTE:MEAS<i>:ENB:SCENario:SALone
External Attenuation (Input)
Defines the value of an external attenuation (or gain, if the value is negative) in the
input path. The power readings of the R&S
CMW are corrected by the external attenu-
ation value.