Command Reference
R&S
®
CMW-KN5xx
68
User Manual 1176.7690.02 ─ 05
<PhaseError>
OFF | ON
Phase Error
*RST:
OFF
<OFDMsymPower>
OFF | ON
OFDM Symbol Power
*RST:
ON
<SpecFlatness>
OFF | ON
Spectrum Flatness
*RST:
ON
<IQ>
OFF | ON
I/Q Constellation Diagram
*RST:
OFF
<TXMeasurement>
OFF | ON
TX Measurement Statistical Overview
*RST:
ON
<SpecEmMask>
OFF | ON
Spectrum Emission Mask
*RST:
ON
<ACLR>
OFF | ON
Adjacent Channel Leakage Power Ratio
*RST:
ON
Example:
See
Performing Single-Shot Measurements
Firmware/Software:
V3.0.20
Manual operation:
See
"Multi Evaluation > Assign Views"
CONFigure:LTE:MEAS<i>:ENB:MEValuation:RESult:EVMagnitude
<Enable>
CONFigure:LTE:MEAS<i>:ENB:MEValuation:RESult:MERRor
<Enable>
CONFigure:LTE:MEAS<i>:ENB:MEValuation:RESult:PERRor
<Enable>
CONFigure:LTE:MEAS<i>:ENB:MEValuation:RESult:OSPower
<Enable>
CONFigure:LTE:MEAS<i>:ENB:MEValuation:RESult:SFLatness
<Enable>
CONFigure:LTE:MEAS<i>:ENB:MEValuation:RESult:IQ
<Enable>
CONFigure:LTE:MEAS<i>:ENB:MEValuation:RESult:TXM
<Enable>
CONFigure:LTE:MEAS<i>:ENB:MEValuation:RESult:SEMask
<Enable>
CONFigure:LTE:MEAS<i>:ENB:MEValuation:RESult:ACLR
<Enable>
Enables or disables the evaluation of results and shows or hides the views in the multi
evaluation measurement.
The mnemonic after "RESult" denotes the view type: Error Vector Magnitude, Magni-
tude Error, Phase Error, OFDM Symbol Power, Spectrum Flatness, I/Q Constellation
Diagram, TX Measurement Statistical Overview, Spectrum Emission Mask, Adjacent
Channel Leakage Power Ratio.
Multi Evaluation Measurement Commands
135-1095-0799