// Define spectrum emission limits
// *****************************************************************************
CONFigure:LTE:MEAS:ENB:MEValuation:LIMit:SEMask:OBWLimit:CBANdwidth14 1.2E+6
CONF:LTE:MEAS:ENB:MEV:LIM:SEM:LIM1:CBAN14 ON,5E+4,15E+5,-28,4.3,OFF,K100
5.7 Performing Single-Shot Measurements
// *****************************************************************************
// Enable all measurements.
// *****************************************************************************
CONF:LTE:MEAS:ENB:MEValuation:RESult:ALL ON,ON,ON,ON,ON,ON,ON,ON,ON
// *****************************************************************************
// Start single-shot measurement, return average EVM bar graph values.
// Query the measurement state (should be "RDY") and the modulation scheme
// configured via the E-UTRA test model.
// *****************************************************************************
READ:LTE:MEAS:ENB:MEValuation:EVMagnitude:AVERage?
FETCh:LTE:MEAS:ENB:MEValuation:STATe?
FETCh:LTE:MEAS:ENB:MEValuation:MODulation?
// *****************************************************************************
// Read modulation traces, bar graph values and statistical values
// obtained in the last measurement without re-starting the measurement.
// *****************************************************************************
FETCh:LTE:MEAS:ENB:MEValuation:EVMagnitude:MAXimum?
FETCh:LTE:MEAS:ENB:MEValuation:MERRor:AVERage?
FETCh:LTE:MEAS:ENB:MEValuation:MERRor:MAXimum?
FETCh:LTE:MEAS:ENB:MEValuation:PERRor:AVERage?
FETCh:LTE:MEAS:ENB:MEValuation:PERRor:MAXimum?
FETCh:LTE:MEAS:ENB:MEValuation:TRACe:OSPower?
FETCh:LTE:MEAS:ENB:MEValuation:TRACe:SFLatness?
FETCh:LTE:MEAS:ENB:MEValuation:TRACe:IQ?
FETCh:LTE:MEAS:ENB:MEValuation:MODulation:CURRent?
FETCh:LTE:MEAS:ENB:MEValuation:MODulation:EXTReme?
// *****************************************************************************
// Read spectrum emission results obtained in the last
// measurement without re-starting the measurement.
// *****************************************************************************
FETCh:LTE:MEAS:ENB:MEValuation:TRACe:SEMask:RBW30:CURRent?
FETCh:LTE:MEAS:ENB:MEValuation:TRACe:SEMask:RBW100:AVERage?
FETCh:LTE:MEAS:ENB:MEValuation:TRACe:SEMask:RBW1000:MAXimum?
FETCh:LTE:MEAS:ENB:MEValuation:SEMask:CURRent?
FETCh:LTE:MEAS:ENB:MEValuation:SEMask:EXTReme?
FETCh:LTE:MEAS:ENB:MEValuation:SEMask:MARGin?
Performing Single-Shot Measurements