Programming
R&S
®
CMW-KN5xx
52
User Manual 1176.7690.02 ─ 05
// allowing for a 5 dB user margin and 1 dB mixer level offset.
// *****************************************************************************
ROUTe:LTE:MEAS:ENB:SCENario:SALone RF1C, RX1
CONFigure:LTE:MEAS:ENB:RFSettings:EATTenuation 2
CONFigure:LTE:MEAS:ENB:RFSettings:FREQuency 1910E+6
CONFigure:LTE:MEAS:ENB:RFSettings:ENPower 7
CONFigure:LTE:MEAS:ENB:RFSettings:UMARgin 5
CONFigure:LTE:MEAS:ENB:RFSettings:MLOFfset 1
// *****************************************************************************
// Set duplex mode TDD.
// *****************************************************************************
CONFigure:LTE:MEAS:ENB:DMODe TDD
5.3 Specifying Required Settings
// *****************************************************************************
// Specify required eNodeB signal settings:
// E-UTRA test model, channel bandwidth, physical cell ID,
// number of used antennas, measured antenna, SYNCH antenna.
// *****************************************************************************
CONFigure:LTE:MEAS:ENB:MEValuation:ETEStmodel ETM12
CONFigure:LTE:MEAS:ENB:MEValuation:CBANdwidth B014
CONFigure:LTE:MEAS:ENB:MEValuation:PLCid 2
CONFigure:LTE:MEAS:ENB:MEValuation:MIMO TA1
CONFigure:LTE:MEAS:ENB:MEValuation:TASelection A1
CONFigure:LTE:MEAS:ENB:MEValuation:TASYnch A1
5.4 Specifying Additional Measurement-Specific Settings
// *****************************************************************************
// Define stop condition (stop on limit failure) and error handling.
// *****************************************************************************
CONFigure:LTE:MEAS:ENB:MEValuation:SCONdition SLFail
CONFigure:LTE:MEAS:ENB:MEValuation:MOEXception ON
CONFigure:LTE:MEAS:ENB:MEValuation:TOUT 3600
// *****************************************************************************
// Specify modulation measurement settings: measurement over 20 subframes and
// EVM window lengths depending on bandwidth.
// Correct EVM window length for 1.4 MHz BW.
// Select EVM window position for the I/Q diagram.
// Use PDSCH rhoA of E-UTRA test model
// *****************************************************************************
CONFigure:LTE:MEAS:ENB:MEValuation:SCOunt:MODulation 20
CONFigure:LTE:MEAS:ENB:MEValuation:MODulation:EWLength 5,12,35,66,102,136
Specifying Required Settings