General Description
R&S
®
CMW-KN5xx
18
User Manual 1176.7690.02 ─ 05
TDD Band
F
Offset
[MHz]
N
Offset
Channel No N
F [MHz]
36
1930
36950
36950 to 37549
1930 to 1989.9
37
1910
37550
37550 to 37749
1910 to 1929.9
38
2570
37750
37750 to 38249
2570 to 2619.9
39
1880
38250
38250 to 38649
1880 to 1919.9
40
2300
38650
38650 to 39649
2300 to 2399.9
41
2496
39650
39650 to 41589
2496 to 2689.9
42
3400
41590
41590 to 43589
3400 to 3599.9
43
3600
43590
43590 to 45589
3600 to 3799.9
44
703
45590
45590 to 46589
703 to 802.9
3.7 Limit Settings and Conformance Requirements
Conformance test requirements for LTE eNodeB transmitter tests are specified in
3GPP TS 36.141 section 6, "Transmitter Characteristics".
The following sections give an overview of the "LTE eNodeB Multi Evaluation" limit set-
tings and the related test requirements.
..................................................................................... 18
.....................................................................................19
........................................................................................20
3.7.1 Transmit Modulation Limits
A poor modulation accuracy of the eNodeB transmitter increases the transmission
errors in the downlink channel of the LTE network and decreases the system capacity.
The Error Vector Magnitude (EVM) is the critical quantity to assess the modulation
accuracy of an eNodeB.
3GPP defines requirements for the frequency error and for the EVM. They shall be
verified for the test models E-TM 2, E-TM 3.1, E-TM 3.2 and E-TM 3.3.
In the configuration dialog you can set limits for both measurement results, depending
on the modulation scheme. You can also set limits for other modulation results.
Limit Settings and Conformance Requirements