Programming
R&S
®
CMW-KN5xx
55
User Manual 1176.7690.02 ─ 05
FETCh:LTE:MEAS:ENB:MEValuation:SEMask:MARGin:MINimum:POSitiv?
FETCh:LTE:MEAS:ENB:MEValuation:SEMask:MARGin:MINimum:NEGativ?
// *****************************************************************************
// Read ACLR results obtained in the last
// measurement without re-starting the measurement.
// *****************************************************************************
FETCh:LTE:MEAS:ENB:MEValuation:TRACe:ACLR:CURRent?
FETCh:LTE:MEAS:ENB:MEValuation:TRACe:ACLR:AVERage?
FETCh:LTE:MEAS:ENB:MEValuation:ACLR:CURRent?
FETCh:LTE:MEAS:ENB:MEValuation:ACLR:AVERage?
// *****************************************************************************
// Read limit check results obtained in the last measurement
// without re-starting the measurement
// *****************************************************************************
CALCulate:LTE:MEAS:ENB:MEValuation:ACLR:CURRent?
CALCulate:LTE:MEAS:ENB:MEValuation:SEMask:CURRent?
CALCulate:LTE:MEAS:ENB:MEValuation:MODulation:CURRent?
5.8 Single-Shot and Continuous Measurements
// *****************************************************************************
// Start single-shot measurement, return magnitude error bar graph values.
// Return maximum magnitude error and phase bar graph values
// (without repeating the measurement).
// Query the measurement state (should be "RDY").
// *****************************************************************************
INIT:LTE:MEAS:ENB:MEValuation
FETCh:LTE:MEAS:ENB:MEValuation:MERRor:CURRent?
FETCh:LTE:MEAS:ENB:MEValuation:MERRor:MAXimum?
FETCh:LTE:MEAS:ENB:MEValuation:PERRor:MAXimum?
FETCh:LTE:MEAS:ENB:MEValuation:STATe?
// *****************************************************************************
// Start continuous measurement and wait for 5 s.
// Return average EVM bar graph results.
// Query measurement state and substates (should be "RUN,ADJ,ACT").
// *****************************************************************************
CONFigure:LTE:MEAS:ENB:MEValuation:REPetition CONTinuous
INIT:LTE:MEAS:ENB:MEValuation
Pause 5000
FETCh:LTE:MEAS:ENB:MEValuation:EVMagnitude:AVERage?
FETCh:LTE:MEAS:ENB:MEValuation:STATe:ALL?
Single-Shot and Continuous Measurements
深圳德标仪器