General Description
R&S
®
CMW-KN5xx
33
User Manual 1176.7690.02 ─ 05
Tables
Most detailed views show tables providing a statistical evaluation of results. The statis-
tical values in the tables are calculated as follows:
●
Current:
Value of the result obtained in the last measurement interval.
●
Average:
Average of all "Current" values referenced to the last statistics cycle.
●
Extreme, Min, Max:
Largest or smallest "Current" value that the R&S
CMW
obtained since the start of the measurement.
●
StdDev:
Standard deviation of all "Current" values since the start of the measure-
ment.
All statistical results (statistical tables and "Average" or "Max" traces) are calculated
according to the general rules for statistical results.
See also: "Statistical Results" in the R&S
CMW user manual, chapter "System Over-
view"
Statistic Count
Progress bar for the measurement. During the first single shot after the start of the
measurement, the bar shows the number of elapsed measured subframes relative to
the "Statistic Count". A filled progress bar indicates that the first shot is complete and
the statistical depth has been reached.
See also: "Statistical Settings" in the R&S
CMW user manual, chapter "System Over-
view"
Out of Tolerance
Percentage of measurement intervals that exceeded the limits.
Modulation
Modulation scheme according to the configured E-UTRA test model.