Command Reference
R&S
®
CMW-KN5xx
72
User Manual 1176.7690.02 ─ 05
CONFigure:LTE:MEAS<i>:ENB:MEValuation:MIMO
<MIMOconfig>
Specifies the number of used TX antennas.
Parameters:
<MIMOconfig>
TA1 | TA2
TA1
: One antenna, SISO
TA2
: Two antennas, MIMO 2x2
*RST:
TA1
Example:
See
Firmware/Software:
V3.2.71
Manual operation:
See
"MIMO Configuration, Tx Antenna Selection"
CONFigure:LTE:MEAS<i>:ENB:MEValuation:TASelection
<TXantennaSelect>
Specifies the number of the measured antenna.
Parameters:
<TXantennaSelect> A1 | A2
A1
: Antenna 1 (SISO antenna or first MIMO 2x2 TX antenna)
A2
: Antenna 2 (second MIMO 2x2 TX antenna)
*RST:
A1
Example:
See
Firmware/Software:
V3.2.71
Manual operation:
See
"MIMO Configuration, Tx Antenna Selection"
CONFigure:LTE:MEAS<i>:ENB:MEValuation:TASYnch
<TXantennaSynch>
Specifies via which antenna the synchronization signals are transferred.
Parameters:
<TXantennaSynch> ALL | A1 | A2
ALL
: All antennas (SISO antenna or both MIMO 2x2 antennas)
A1
: Antenna 1 (SISO antenna or first MIMO 2x2 TX antenna)
A2
: Antenna 2 (second MIMO 2x2 TX antenna)
Example:
See
Firmware/Software:
V3.2.71
Manual operation:
See
6.3.4 Modulation Measurement Settings
The following commands specify settings for the modulation measurements.
Multi Evaluation Measurement Commands