Command Reference
R&S
®
CMW-KN5xx
100
User Manual 1176.7690.02 ─ 05
READ:LTE:MEAS<i>:ENB:MEValuation:SEMask:AVERage?
READ:LTE:MEAS<i>:ENB:MEValuation:SEMask:SDEViation?
Return the current, average and standard deviation single value results of the spec-
trum emission measurement.
The values described below are returned by
FETCh
and
READ
commands.
CALCulate
commands return limit check results instead, one value for each result listed below.
The ranges indicated below apply to all results except standard deviation results. The
minimum for standard deviation results equals 0. The maximum equals the width of the
indicated range divided by two. Exceptions are explicitly stated.
Return values:
<Reliability>
<OutOfTolerance>
Out of tolerance result, i.e. percentage of measurement inter-
vals of the statistic count for spectrum emission measurements
exceeding the specified spectrum emission mask limits.
Range:
0 % to 100 %
Default unit: %
<OBW>
Occupied bandwidth
Range:
0 MHz to 40 MHz
Default unit: Hz
<TXpower>
Total TX power in the subframe
Range:
-100 dBm to 55 dBm
Default unit: dBm
Example:
See
Performing Single-Shot Measurements
Usage:
Query only
Firmware/Software:
V3.0.20
For additional information concerning syntax elements and returned values refer to
Conventions and General Information
.
CALCulate:LTE:MEAS<i>:ENB:MEValuation:SEMask:EXTReme?
FETCh:LTE:MEAS<i>:ENB:MEValuation:SEMask:EXTReme?
READ:LTE:MEAS<i>:ENB:MEValuation:SEMask:EXTReme?
Return the extreme single value results of the spectrum emission measurement.
The values described below are returned by
FETCh
and
READ
commands.
CALCulate
commands return limit check results instead, one value for each result listed below.
Return values:
<Reliability>
<OutOfTolerance>
Out of tolerance result, i.e. percentage of measurement inter-
vals of the statistic count for spectrum emission measurements
exceeding the specified spectrum emission mask limits.
Range:
0 % to 100 %
Default unit: %
Multi Evaluation Measurement Commands