Fig. 3-8: Modulation limit settings for QPSK
The following table provides an overview of the related limits defined by 3GPP. The
default values correspond to the requirements for a home BS.
Characteristics
Refer to 3GPP TS 36.141 V10.6.0,
section...
Modulation or BS Class
Test Requirement
EVM (RMS)
6.5.2 Error Vector Magnitude
QPSK
< 18.5 %
16-QAM
< 13.5 %
64-QAM
< 9 %
Frequency Error
6.5.1 Frequency Error
home BS
< 0.25 ppm
local area BS
< 0.1 ppm
wide area BS
< 0.05 ppm
3.7.2 Occupied Bandwidth Limits
The occupied bandwidth is the width of a symmetric frequency interval around the
nominal RF carrier frequency that contains 99 % of the total integrated power of the
transmitted spectrum.
According to 3GPP the occupied bandwidth shall be less than the (theoretical) channel
bandwidth. This shall be verified with the test model E-TM1.1.
In the configuration dialog you can set a limit for the occupied bandwidth, depending
on the channel bandwidth.
Fig. 3-9: Occupied bandwidth limit setting for 1.4 MHz channel bandwidth
Characteristics
Refer to 3GPP TS 36.141 V10.6.0, section...
Test Requirement
Occupied Bandwidth (OBW)
6.6.1 Occupied Bandwidth
< channel bandwidth