Command Reference
R&S
®
CMW-KM750/-KM751
104
User Manual 1173.9670.02 ─ 05
FETCh:TDSCdma:MEAS<i>:MEValuation:TRACe:EVMagnitude:CURRent?
FETCh:TDSCdma:MEAS<i>:MEValuation:TRACe:EVMagnitude:AVERage?
FETCh:TDSCdma:MEAS<i>:MEValuation:TRACe:EVMagnitude:MAXimum?
READ:TDSCdma:MEAS<i>:MEValuation:TRACe:EVMagnitude:CURRent?
READ:TDSCdma:MEAS<i>:MEValuation:TRACe:EVMagnitude:AVERage?
READ:TDSCdma:MEAS<i>:MEValuation:TRACe:EVMagnitude:MAXimum?
Returns the values of the RMS EVM vs. chip traces, measured in the preselected slot
(see
One value per chip is returned. The results of the current, average and maximum traces
can be retrieved.
See also
chapter 3.6.2, "Detailed Views: Modulation, CDP and CDE, Power vs Time"
Return values:
<Reliability>
<EVM1> ...
<EVM848>
Range:
0 % to 100 %
Default unit: %
Example:
See
Performing Single-Shot Measurements
Usage:
Query only
Firmware/Software:
V1.0.2.7
For additional information concerning syntax elements and returned values refer to
ventions and General Information
FETCh:TDSCdma:MEAS<i>:MEValuation:TRACe:EVMagnitude[:RMS]:MSLot:
CURRent?
FETCh:TDSCdma:MEAS<i>:MEValuation:TRACe:EVMagnitude[:RMS]:MSLot:
AVERage?
FETCh:TDSCdma:MEAS<i>:MEValuation:TRACe:EVMagnitude[:RMS]:MSLot:
EXTReme?
FETCh:TDSCdma:MEAS<i>:MEValuation:TRACe:EVMagnitude[:RMS]:MSLot:
SDEViation?
READ:TDSCdma:MEAS<i>:MEValuation:TRACe:EVMagnitude[:RMS]:MSLot:
CURRent?
READ:TDSCdma:MEAS<i>:MEValuation:TRACe:EVMagnitude[:RMS]:MSLot:
AVERage?
Multi Evaluation Measurement Commands