Command Reference
R&S
®
CMW-KM750/-KM751
105
User Manual 1173.9670.02 ─ 05
READ:TDSCdma:MEAS<i>:MEValuation:TRACe:EVMagnitude[:RMS]:MSLot:
EXTReme?
READ:TDSCdma:MEAS<i>:MEValuation:TRACe:EVMagnitude[:RMS]:MSLot:
SDEViation?
Returns the values of the RMS EVM vs. slot traces.
Each trace contains 112 values, one per slot. The number of measured slots is related
to the number of measured subframes (see
on page 83). For not measured slots the value "NCAP" is
returned.
The results of the current, average, extreme and standard deviation traces can be
retrieved.
See also
chapter 3.6.2, "Detailed Views: Modulation, CDP and CDE, Power vs Time"
Return values:
<Reliability>
<EVM1> ...
<EVM112>
Range:
0 % to 100 % (SDEViation: 0 % to 50 %)
Default unit: %
Example:
See
Performing Single-Shot Measurements
Usage:
Query only
Firmware/Software:
V1.0.4.11
For additional information concerning syntax elements and returned values refer to
ventions and General Information
6.3.11 Magnitude Error Results (Traces)
The following commands return the magnitude error trace results of the multi evaluation
measurement.
...............................106
..............................106
..............................106
................................106
................................106
...............................106
Multi Evaluation Measurement Commands