Command Reference
R&S
®
CMW-KM750/-KM751
112
User Manual 1173.9670.02 ─ 05
...............................113
..............................113
.............................113
FETCh:TDSCdma:MEAS<i>:MEValuation:TRACe:CDMonitor:CDERror?
<SF>
READ:TDSCdma:MEAS<i>:MEValuation:TRACe:CDMonitor:CDERror?
<SF>
Returns the values of the code domain error monitor diagrams. A separate diagram is
available for each spreading factor.
See also
chapter 3.6.2, "Detailed Views: Modulation, CDP and CDE, Power vs Time"
Query parameters:
<SF>
SF1 | SF2 | SF4 | SF8 | SF16
Selects the spreading factor for which the trace shall be retrieved
*RST:
n/a
Return values:
<Reliability>
<CDE_1> ...
<CDE_SF>
One value per code channel. The number of values/channels cor-
responds to the spreading factor (e.g. 8 values/channels for SF8).
Range:
-100 dB to 0 dB
Default unit: dB
Example:
See
Performing Single-Shot Measurements
Usage:
Query only
Firmware/Software:
V1.0.2.7
For additional information concerning syntax elements and returned values refer to
ventions and General Information
FETCh:TDSCdma:MEAS<i>:MEValuation:TRACe:CDERror:CURRent?
FETCh:TDSCdma:MEAS<i>:MEValuation:TRACe:CDERror:AVERage?
FETCh:TDSCdma:MEAS<i>:MEValuation:TRACe:CDERror:MINimum?
FETCh:TDSCdma:MEAS<i>:MEValuation:TRACe:CDERror:MAXimum?
FETCh:TDSCdma:MEAS<i>:MEValuation:TRACe:CDERror:SDEViation?
READ:TDSCdma:MEAS<i>:MEValuation:TRACe:CDERror:CURRent?
READ:TDSCdma:MEAS<i>:MEValuation:TRACe:CDERror:AVERage?
Multi Evaluation Measurement Commands