Command Reference
R&S
®
CMW-KM750/-KM751
120
User Manual 1173.9670.02 ─ 05
<11_CarrFreqError> Carrier frequency error
Range:
-5000 Hz to 5000 Hz
Default unit: Hz
<12_UEpower>
User equipment power
Range:
-100 dBm to 35 dBm
Default unit: dBm
<13_Slot>
Number of measured slot
Range:
0 to 111
<14_PCDE>
Peak code domain error
Range:
-60 dB to 0 dB
Default unit: dB
<15_PCDEcode>
Number of the code channel where the PCDE occurred.
Range:
0 to 15
<16_WaveformQual> Waveform quality
Range:
0 to 1
Example:
See
Performing Single-Shot Measurements
Usage:
Query only
Firmware/Software:
V1.0.10.1
V3.0.10: added <16_WaveformQual>
For additional information concerning syntax elements and returned values refer to
ventions and General Information
FETCh:TDSCdma:MEAS<i>:MEValuation:MODulation:AVERage?
FETCh:TDSCdma:MEAS<i>:MEValuation:MODulation:SDEViation?
READ:TDSCdma:MEAS<i>:MEValuation:MODulation:AVERage?
READ:TDSCdma:MEAS<i>:MEValuation:MODulation:SDEViation?
CALCulate:TDSCdma:MEAS<i>:MEValuation:MODulation:AVERage?
CALCulate:TDSCdma:MEAS<i>:MEValuation:MODulation:SDEViation?
Return the average and standard deviation modulation single value results.
The values described below are returned by
FETCh
and
READ
commands.
CALCulate
commands return limit check results instead, one value for each result listed below.
The ranges indicated below apply to all results except standard deviation results. The
minimum for standard deviation results equals 0. The maximum equals the width of the
indicated range divided by two. Exceptions are explicitly stated.
The number to the left of each result parameter is provided for easy identification of the
parameter position within the result array.
Return values:
<1_Reliability>