Command Reference
R&S
®
CMW-KM750/-KM751
134
User Manual 1173.9670.02 ─ 05
Return values:
<Reliability>
<CarrierFreqErr>
Comma separated list of values, one per measured segment
Range:
-5000 Hz to 5000 Hz
Default unit: Hz
Example:
See
Usage:
Query only
Firmware/Software:
V3.0.10
Options:
R&S CMW-KM012
FETCh:TDSCdma:MEAS<i>:MEValuation:LIST:MODulation:TERRor:CURRent?
FETCh:TDSCdma:MEAS<i>:MEValuation:LIST:MODulation:TERRor:AVERage?
FETCh:TDSCdma:MEAS<i>:MEValuation:LIST:MODulation:TERRor:MAXimum?
FETCh:TDSCdma:MEAS<i>:MEValuation:LIST:MODulation:TERRor:SDEViation?
Return transmit time error values for all measured list mode segments.
Return values:
<Reliability>
<TransmitTimeErr>
Comma separated list of values, one per measured segment
Range:
-500 chips to 500 chips
Default unit: chips
Example:
See
Usage:
Query only
Firmware/Software:
V3.0.10
Options:
R&S CMW-KM012
FETCh:TDSCdma:MEAS<i>:MEValuation:LIST:MODulation:UEPower:CURRent?
FETCh:TDSCdma:MEAS<i>:MEValuation:LIST:MODulation:UEPower:AVERage?
FETCh:TDSCdma:MEAS<i>:MEValuation:LIST:MODulation:UEPower:MAXimum?
FETCh:TDSCdma:MEAS<i>:MEValuation:LIST:MODulation:UEPower:
SDEViation?
Return user equipment power values for all measured list mode segments.
Return values:
<Reliability>
<UEpower>
Comma separated list of values, one per measured segment
Range:
-100 dBm to 35 dBm
Default unit: dBm
Example:
See
Usage:
Query only
Multi Evaluation Measurement Commands