Command Reference
R&S
®
CMW-KM750/-KM751
124
User Manual 1173.9670.02 ─ 05
To configure the list mode use the commands described in
For a description of the list mode see
chapter 3.3, "Multi Evaluation List Mode"
Indicated ranges apply to all statistical results except standard deviation results. The
minimum for standard deviation results equals 0. The maximum equals the width of the
indicated range divided by two. Exceptions are explicitly stated.
FETCh:TDSCdma:MEAS<i>:MEValuation:LIST:SEGMent<Segno>:MODulation:
CURRent?
FETCh:TDSCdma:MEAS<i>:MEValuation:LIST:SEGMent<Segno>:MODulation:
MAXimum?
Return current and maximum modulation single value results for segment <Segno> in
list mode.
Suffix:
<Segno>
.
1..500
Return values:
<1_Reliability>
In list mode, a zero reliability indicator indicates that the results in
all measured segments are valid. A non-zero value indicates that
an error occurred in at least one of the measured segments.
<2_SegReliability>
Reliability indicator for the segment. The meaning of the returned
values is the same as for the common reliability indicator, see
previous parameter.
<3_EVMRMS>
<4_EVMPeak>
Error vector magnitude RMS and peak value
Range:
0 % to 100 %
Default unit: %
<5_MagErrRMS>
Magnitude error RMS value
Range:
0 % to 100 %
Default unit: %
Multi Evaluation Measurement Commands