Command Reference
R&S
®
CMW-KM750/-KM751
87
User Manual 1173.9670.02 ─ 05
CONFigure:TDSCdma:MEAS<i>:MEValuation:BER:DATA
<Data Pattern>
Selects the expected data pattern for looped-back RX test signals.
Parameters:
<Data Pattern>
ONE | ZERO | ZONE | ONEZero | PN9 | PN15
ONE
: all 1
ZERO
: all 0
ZONE
: alternating 01
ONEZero
: alternating 10
PN9 | PN15
: pseudo-random bit sequences generated with the
indicated number of shift-register stages
*RST:
ONE
Example:
See
Specifying Additional Measurement-Specific Settings
Firmware/Software:
V2.1.10
Manual operation:
See
CONFigure:TDSCdma:MEAS<i>:MEValuation:TRCHmode
<TrCHMode>
Selects the expected transport channel configuration for looped-back RX test signals.
Set this parameter according to the downlink signal (the ARB file).
Parameters:
<TrCHMode>
RMC | USER
RMC
: DTCH and DCCH
USER
: DTCH only
Example:
See
Specifying Additional Measurement-Specific Settings
Firmware/Software:
V3.0.10
Manual operation:
See
6.3.4 List Mode Settings
The following commands configure the list mode. For retrieving list mode results see
chapter 6.3.20, "List Mode Results (One Segment)"
, on page 123 and subsequent sec-
tions.
............................................................87
.................................................88
......................................................92
CONFigure:TDSCdma:MEAS<i>:MEValuation:LIST
<ListmodeEnable>
Enables or disables the list mode.
Multi Evaluation Measurement Commands