![Rohde & Schwarz CMW-KM750 User Manual Download Page 130](http://html.mh-extra.com/html/rohde-and-schwarz/cmw-km750/cmw-km750_user-manual_1477810130.webp)
Command Reference
R&S
®
CMW-KM750/-KM751
130
User Manual 1173.9670.02 ─ 05
FETCh:TDSCdma:MEAS<i>:MEValuation:LIST:MODulation:EVM:RMS:CURRent?
FETCh:TDSCdma:MEAS<i>:MEValuation:LIST:MODulation:EVM:RMS:AVERage?
FETCh:TDSCdma:MEAS<i>:MEValuation:LIST:MODulation:EVM:RMS:
MAXimum?
FETCh:TDSCdma:MEAS<i>:MEValuation:LIST:MODulation:EVM:RMS:
SDEViation?
Return error vector magnitude RMS values for all measured list mode segments.
Return values:
<Reliability>
<EVMrms>
Comma separated list of values, one per measured segment
Range:
0 % to 100 %
Default unit: %
Example:
See
Usage:
Query only
Firmware/Software:
V3.0.10
Options:
R&S CMW-KM012
FETCh:TDSCdma:MEAS<i>:MEValuation:LIST:MODulation:EVM:PEAK:
CURRent?
FETCh:TDSCdma:MEAS<i>:MEValuation:LIST:MODulation:EVM:PEAK:
AVERage?
FETCh:TDSCdma:MEAS<i>:MEValuation:LIST:MODulation:EVM:PEAK:
MAXimum?
FETCh:TDSCdma:MEAS<i>:MEValuation:LIST:MODulation:EVM:PEAK:
SDEViation?
Return error vector magnitude peak values for all measured list mode segments.
Return values:
<Reliability>
<EVMpeak>
Comma separated list of values, one per measured segment
Range:
0 % to 100 %
Default unit: %
Example:
See
Usage:
Query only
Firmware/Software:
V3.0.10
Options:
R&S CMW-KM012
FETCh:TDSCdma:MEAS<i>:MEValuation:LIST:MODulation:MERRor:RMS:
CURRent?
FETCh:TDSCdma:MEAS<i>:MEValuation:LIST:MODulation:MERRor:RMS:
AVERage?