![Rohde & Schwarz CMW-KM750 User Manual Download Page 132](http://html.mh-extra.com/html/rohde-and-schwarz/cmw-km750/cmw-km750_user-manual_1477810132.webp)
Command Reference
R&S
®
CMW-KM750/-KM751
132
User Manual 1173.9670.02 ─ 05
FETCh:TDSCdma:MEAS<i>:MEValuation:LIST:MODulation:PERRor:RMS:
MAXimum?
FETCh:TDSCdma:MEAS<i>:MEValuation:LIST:MODulation:PERRor:RMS:
SDEViation?
Return phase error RMS values for all measured list mode segments.
Return values:
<Reliability>
<PhaseErrorRMS>
Comma separated list of values, one per measured segment
Range:
0 deg to 180 deg
Default unit: deg
Example:
See
Usage:
Query only
Firmware/Software:
V3.0.10
Options:
R&S CMW-KM012
FETCh:TDSCdma:MEAS<i>:MEValuation:LIST:MODulation:PERRor:PEAK:
CURRent?
FETCh:TDSCdma:MEAS<i>:MEValuation:LIST:MODulation:PERRor:PEAK:
AVERage?
FETCh:TDSCdma:MEAS<i>:MEValuation:LIST:MODulation:PERRor:PEAK:
MAXimum?
FETCh:TDSCdma:MEAS<i>:MEValuation:LIST:MODulation:PERRor:PEAK:
SDEViation?
Return phase error peak values for all measured list mode segments.
Return values:
<Reliability>
<PhaseErrorPeak>
Comma separated list of values, one per measured segment
Range:
-180 deg to 180 deg (AVERage: 0 deg to 180 deg,
SDEViation: 0 deg to 90 deg)
Default unit: deg
Example:
See
Usage:
Query only
Firmware/Software:
V3.0.10
Options:
R&S CMW-KM012
FETCh:TDSCdma:MEAS<i>:MEValuation:LIST:MODulation:IQOFfset:CURRent?
FETCh:TDSCdma:MEAS<i>:MEValuation:LIST:MODulation:IQOFfset:AVERage?
Multi Evaluation Measurement Commands