<PhaErrPeak>
Range:
0 deg to 20 deg
*RST:
10 deg
Default unit: deg
Additional parameters: OFF | ON (disables | enables the limit
check using the previous/default limit values)
Example:
See
Firmware/Software:
V1.0.2.7
CONFigure:TDSCdma:MEAS<i>:MEValuation:LIMit:IQOFfset
<IQOffset>
Defines an upper limit for the I/Q origin offset.
Parameters:
<IQOffset>
Range:
-80 dB to 0 dB
*RST:
-25 dB
Default unit: dB
Additional parameters: OFF | ON (disables | enables the limit
check using the previous/default limit values)
Example:
See
Firmware/Software:
V1.0.2.7
CONFigure:TDSCdma:MEAS<i>:MEValuation:LIMit:IQIMbalance
<IQImbalance>
Defines an upper limit for the I/Q imbalance.
Parameters:
<IQImbalance>
Range:
-99 dB to 0 dB
*RST:
-15 dB
Default unit: dB
Additional parameters: OFF | ON (disables | enables the limit
check using the previous/default limit values)
Example:
See
Firmware/Software:
V1.0.2.7
CONFigure:TDSCdma:MEAS<i>:MEValuation:LIMit:FERRor
<FreqError>
Defines an upper limit for the carrier frequency error.
Parameters:
<FreqError>
Range:
0 Hz to 4000 Hz
*RST:
200 Hz
Default unit: Hz
Additional parameters: OFF | ON (disables | enables the limit
check using the previous/default limit values)
Example:
See
Firmware/Software:
V1.0.2.7