Palletizing Solution - Instruction Manual
Inter-Controller Connections
1. Open the UR controller. Connect the USB hub to a USB port.
2. Connect the Ethernet/USB converter cable to a USB port.
3. Connect the Ethernet cable into the Ethernet socket on the top of the linear axis Controller.
4. Pass the other extremity of the cable through the hole under the UR controller and connect it into the Ethernet/USB converter
cable that is already connected.
Info
Follow cable management good practices. You can either drill a hole in the hole plug or use a grommet (not included).
Fig. 3-1: Linear Axis Controller Cable Summary
Safety Signal Connections
1. Take the signal safety cable and pass it through an opening under the UR controller.
2. Wire the cable by following the schema and the table available in the Appendix section.
Caution
l
Follow the installation guidelines in the UR manual for Emergency stop or Safeguard connections. Use the connector
supplied by Robotiq for Safeguard connections.
l
If the safeguard is not used, add jumpers between pin 1-2 and 3-4.
l
Do not forget to connect the safety reset wire (white color) according to your safety setup. For more details, please refer
to the table in the Safety Connections section.
44
Summary of Contents for PALLETIZING SOLUTION AX Series
Page 4: ...Palletizing Solution Instruction Manual 4 ...
Page 14: ...Palletizing Solution Instruction Manual 14 ...
Page 21: ...Palletizing Solution Instruction Manual 21 ...
Page 33: ...Base Cover Plate 1 Remove the cover plate that will allow the cable management 33 ...
Page 84: ...6 1 2 AirPick Vacuum Gripper Fig 6 1 AirPick general dimensions 84 ...
Page 85: ...Palletizing Solution Instruction Manual 6 1 3 Extra Reach Bracket 85 ...
Page 86: ...6 1 4 Bracket for Two 2 Suction Cups Fig 6 2 Two air nodes bracket s dimensions 86 ...
Page 113: ...12 2 Safety Connections Fig 12 2 Universal Robots Controller Safety Connections Schema ...