Palletizing Solution - Instruction Manual
Error message:
"RTDE interface cannot initialize. Make
sure that Ethernet/IP adapter and
Profinet are disabled, and that no tother
URCaps use the RTDE interface."
We employ registers that cannot be used
with Ethernet/IP or Profinet at the same
time when the following function
checkbox is ticked:
Installation > URCaps > Copilot >
Configuration > General: "Use Copilot to
manage a soft speed transition when
resuming from a Safeguard stop"
l
Update to the latest version of the
Copilot software.
l
Untick the "Use Copilot to manage a
soft speed transition when resuming
from a Safeguard stop" checkbox.
Error message:
"org.apache.xmlrpc.CmlRpcExecption:
One parameter is invalid in the fromjson
request"
The Linear Axis may be below its home
position (0 mm).
l
Bring the Linear Axis above its home
position (0 mm) before starting the
program.
l
Update to the latest version of the
Copilot software.
9.2. AirPick Vacuum Gripper
9.2.1. Communication
When using AirPick Vacuum gripper with USB to RS485 serial converter:
Troubleshooting from the Gripper LED:
1. LED is not lit, Gripper not powered.
a. Check Gripper power supply and electrical setup
2. LED is solid blue and red, Gripper is in fault.
a. Disconnect the communication and power cycle the Gripper. The LED should turn solid red when powered.
b. While powered with red LED, connect the communication, LED should turn solid blue when connection is
established.
3. Flashing blue and red LED, Gripper is in fault.
a. Gripper may be in auto-release, wait for auto-release to be completed, then turn off auto-release and initialize the
Gripper.
b. Gripper may have a major fault, check the error from fault status and contact support.
4. Solid blue, no fault and communicating.
a. If you can control the Gripper from the GUI on the pendant, check your program structure.
b. If you can not control the Gripper from the pendant, contact support.
Summary of Contents for PALLETIZING SOLUTION AX Series
Page 4: ...Palletizing Solution Instruction Manual 4 ...
Page 14: ...Palletizing Solution Instruction Manual 14 ...
Page 21: ...Palletizing Solution Instruction Manual 21 ...
Page 33: ...Base Cover Plate 1 Remove the cover plate that will allow the cable management 33 ...
Page 84: ...6 1 2 AirPick Vacuum Gripper Fig 6 1 AirPick general dimensions 84 ...
Page 85: ...Palletizing Solution Instruction Manual 6 1 3 Extra Reach Bracket 85 ...
Page 86: ...6 1 4 Bracket for Two 2 Suction Cups Fig 6 2 Two air nodes bracket s dimensions 86 ...
Page 113: ...12 2 Safety Connections Fig 12 2 Universal Robots Controller Safety Connections Schema ...