Palletizing Solution - Instruction Manual
Wire #
Color
Function
Description
1
White
Safeguard Reset
When using a safeguard reset button, connect wire #1 to the same configurable input as the
button.
To enable an automatic safeguard reset of the Solution using an area scanner:
l
Connect wire #1 to an available 24 V terminal in the UR controller. The system will auto-start
when no safeguard signal is triggered.
2
Brown
0V
0V link between both electrical enclosures.
3
Green
UR E-Stop Status 1
E-Stop status signal when an emergency signal is applied to EI0.
4
Yellow
UR E-Stop Status 2
E-Stop status signal when an emergency signal is applied to EI1.
5
Grey
UR Safeguard input 1
UR does not support safeguard statuses in configurable outputs. Connect this pin to the regular
safeguard input SI0 for status.
6
Orange
UR Safeguard input 2
UR does not support safeguard statuses in configurable outputs. Connect this pin to the regular
safeguard input SI1 for status.
Table 12-1: Safety Wires Description
Summary of Contents for PALLETIZING SOLUTION AX Series
Page 4: ...Palletizing Solution Instruction Manual 4 ...
Page 14: ...Palletizing Solution Instruction Manual 14 ...
Page 21: ...Palletizing Solution Instruction Manual 21 ...
Page 33: ...Base Cover Plate 1 Remove the cover plate that will allow the cable management 33 ...
Page 84: ...6 1 2 AirPick Vacuum Gripper Fig 6 1 AirPick general dimensions 84 ...
Page 85: ...Palletizing Solution Instruction Manual 6 1 3 Extra Reach Bracket 85 ...
Page 86: ...6 1 4 Bracket for Two 2 Suction Cups Fig 6 2 Two air nodes bracket s dimensions 86 ...
Page 113: ...12 2 Safety Connections Fig 12 2 Universal Robots Controller Safety Connections Schema ...