Pallet Sensors and Base Cables Routing
1. Connect the pallet sensors. The cables are identified for each side. Make sure to connect each pair of cables correctly.
2. Bring out the air tube and the box sensor cable from the bottom of the column and continue to channel it until you bring it out
from the other extremity of the base (through the rectangle hole).
3. Plug the power cable into the wall outlet.
Centering the Solution
This procedure needs to be done before the AirPick Vacuum Gripper installation. It will ensure proper functioning of the solution.
The goal is to properly align the column with the base by placing the robot wrist at a specific position at the same time as it touches
the side of the base.
1. Unscrew half a turn the four (4) screws that secure the column onto the base.
Warning
Do not unscrew completely. Unscrew only half a turn to be able to change the orientation of the column. Completely
untightening the screws can cause the column to fall and cause bodily injuries and material damages.
2. Rotate the column counterclockwise as much as possible.
37
Summary of Contents for PALLETIZING SOLUTION AX Series
Page 4: ...Palletizing Solution Instruction Manual 4 ...
Page 14: ...Palletizing Solution Instruction Manual 14 ...
Page 21: ...Palletizing Solution Instruction Manual 21 ...
Page 33: ...Base Cover Plate 1 Remove the cover plate that will allow the cable management 33 ...
Page 84: ...6 1 2 AirPick Vacuum Gripper Fig 6 1 AirPick general dimensions 84 ...
Page 85: ...Palletizing Solution Instruction Manual 6 1 3 Extra Reach Bracket 85 ...
Page 86: ...6 1 4 Bracket for Two 2 Suction Cups Fig 6 2 Two air nodes bracket s dimensions 86 ...
Page 113: ...12 2 Safety Connections Fig 12 2 Universal Robots Controller Safety Connections Schema ...