Block
Access
Description
Generator
parameters
Start amplitude: Start amplitude for soft start (see
illustration below).
▪ 10% to 40% (normal value 30%)
Zeit [ms]
Amplitud
e
[%]
Sollamplitude
Rampenstartwert
Sollstartzeit
5 – 200 ms
Sollstoppzeit
0 – 50 ms
Sollschweisszeit, Sollenergie
Abbildung Seite 79
Soft start time:
▪ 5 to 200 ms (standard value 20 ms)
Soft stop time:
▪ 0 to 50 ms (standard value 0 ms)
For gentle oscillation expansion and contraction of
complicated sonotrodes.
Frequency reset:
Normally, the frequency is adjusted to the last
level. If this is not required, set "Frequency reset"
to "On".
Upper frequency limit:
▪ +50 to +500 Hz
Lower frequency limit:
▪ –50 to –500 Hz
Overload switch-off delay:
To suppress extremely short power peaks (in
continuous mode).
▪ 5 to 9999 ms
Overload level:
Maximum power value for limiting operation of the
generator.
▪ 5 W min. to 1.2 x generator's nominal power
Cable length:
1 m to 15 m
Slow control:
Factor for reducing the control velocity of the
frequency control with oscillating sonotrodes.
▪ 1: fast frequency control (recommended)
▪ 2 to 20: slow frequency control (the higher it is
set, the slower the frequency)
Power limit:
If the output power exceeds the set value, the
generator reduces the amplitude.
▪ 5 W min. to generator's nominal power:
0 = no power limit
Tab. 16:
System functions (PIN) - generator parameters
Generator parameters