6 | Operation
RINCO ULTRASONICS AG
78 / 137
BA_Standard3000_GB_V5.1_36566
Block
Access
Description
Holding status:
The sonotrode can be held on the part in different
ways to influence the solidification of the welding.
▪ Time
▪ Travel diff.
▪ Travel abs.
▪ Off
Rest position:
Switch off rest position monitoring in special
machine configurations.
Error level:
Voltage level of the error output ERROR_OUT at
STO_2_2 Pin 4 in case of error
▪ High: 24 VDC/error; 0 VDC/no error
▪ Low: 0 VDC/error; 24 VDC/no error
Fan mode:
Fan control
▪
Always on:
Fan is always on.
▪
Automatic:
Fan switches on when the tempera-
ture exceeds 50 °C.
Tab. 13:
System functions (PIN) Option 1
Block
Access
Description
Options 2
Start mode:
▪ Manual (CE)
▪ Automatic:
CE conformity is no longer ensured. The system
operator must adapt the machine concept so
that it is compliant with the CE Machinery
Directive. When switching to Automatic, the
online data window is switched off by default.
Error position:
Press position in case of blocking after "error".
Data string:
Welding data transfer via RS 232 on an external
hardware system.
Interval data string:
Readout interval, a data string is always sent in the
case of faulty weldings.
▪ 000 none
▪ 001 every
Switch data set function:
Switch via external control, e.g. via a PLC
▪ Off
▪ dec (decimal)
▪ bin (binary)
▪ RS232
Sound enclosure:
Program for operating the sound enclosure SSK.
Options 2