8 | Faults
RINCO ULTRASONICS AG
108 / 137
BA_Standard3000_GB_V5.1_36566
S.:
No. Error message
Cause
Measures
004: 001 Lifting door not up when
cycle starts
When the welding cycle
starts, the lifting door is not
in the upper position
▪ Check sensor, replace if necessary
▪ Check compressed air supply
▪ Check solenoid valve, replace if
necessary
▪ Check cylinder
▪ Check connections ("System
status" menu)
004: 002 Time overrun, lower lifting
door
Lifting door does not move
to lower position within the
required time
▪ Parts may be blocking the lifting
door
▪ Adjust the stroke speed via the
throttle
▪ Check compressed air supply
▪ Check solenoid valve, replace if
necessary
▪ Check cylinder
▪ Check connections ("System
status" menu)
▪ Check generator, replace if
necessary
004: 003 Time overrun, raise lifting
door
Lifting door does not move
to upper position within the
required time
▪ Parts may be blocking the lifting
door
▪ Adjust the stroke speed via the
throttle
▪ Check compressed air supply
▪ Check solenoid valve, replace if
necessary
▪ Check cylinder
▪ Check connections ("System
status" menu)
▪ Check generator, replace if
necessary
004: 004 Cabin door open
The service door of the
sound enclosure is not
closed
▪ Check switch
▪ Check connection ("System status"
menu)
▪ Check generator, replace if
necessary
004: 005 Lifting door opened during
welding cycle
During the welding process,
the sensor signal for the
lifting door has disabled
▪ Check compressed air supply
▪ Was the lifting door opened
manually?
▪ Check connection ("System status"
menu)
▪ Check valves, replace if necessary
▪ Check generator, replace if
necessary
Tab. 33:
Sound enclosure error