BA_Standard3000_GB_V5.1_36566
Outputs at STO_2_2 (DSUB25)
Fig. 77:
Pin assignment of outputs on STO_2_2 (DSUB25)
PIN
Signal
Description
1
+24VDC_IO_IN
External voltage 24VDC
2
+24VDC_IO_IN
External voltage 24VDC
3
ERROR_HIGHPRIO_OUT
Error with highest priority (switch off generator)
4
ERROR_OUT
Error
5
ERROR_CODE1_OUT
Error code
6
ERROR_CODE2_OUT
Error code
7
ERROR_CODE3_OUT
Error code
8
READY_OUT
Ready for new cycle
9
US_ACTIVE_OUT
Ultrasound active
10
RESTPOS_OUT
Rest position of press
11
RESERVE_11_OUT
12
START_OUT
Cycle start
13
MV_OUT
Press solenoid valve actuated (cylinder travels forward/is down)
14
START_RETURN_OUT
Return stroke of active press (cylinder returns/is up)
15
GOOD_PART_COUNT_OUT Successful cycle completed
16
BAD_PART_COUNT_OUT
Faulty cycle completed
17
RESERVE_17_OUT
18
RESERVE_18_OUT
19
RESERVE_19_OUT
20
SSK_MV_LIFTDOOR_OUT
Solenoid valve, lifting doors (option activated)
21
HOLD_ACTIVE_OUT
Displays the hold time (solidification)
22
RESERVE_22_OUT
23
POWER_AOUT
Analogue power output 0-10 VDC (0-120% power)
24
GND24VDC_IO_IN
External voltage supply GND
25
GND24VDC_IO_IN
External voltage supply GND
Tab. 57:
Pin assignment STO_2_2