RINCO ULTRASONICS AG
Operation | 6
BA_Standard3000_GB_V5.1_36566
77 / 137
Advanced system operation
The relevant PIN can be used to authorise further access to the sequences
System Parameters and Amplitude Measurement.
The menu enables advanced access:
▪ Setting up
▪ Welding parameters
▪ Limits
▪ Information
▪ Database
▪ System parameters
▪ Amplitude measurement
For the "Database installation" descriptions, see chapter
Parameterization
PIN [
}
76]
.
System functions (PIN)
Block
Access
Description
Options 1
Press type:
Enter the welding device used.
Trigger mode
Select the ultrasound trigger point:
▪
Pressure:
The ultrasound is triggered according
to a preset trigger value (differential pressure).
▪
Time:
After a specific time has elapsed from the
start of the cycle.
▪
Travel:
After a programmed distance from the
top rest position.
▪
Off:
No trigger available.
▪
External:
Digital input
Trigger mode before/after SSW:
Select SSW status for ultrasound trigger point:
▪
before:
For a welding stroke longer than 6 mm.
The ultrasound starts before the 6 mm safety
switch (SSW).
▪
after:
For all welding operations within 6 mm
stroke. The ultrasound starts after the 6 mm
safety switch (SSW).
After pulse:
Light ultrasonic pulse during return stroke of the
press. Prevents the plastic part from sticking to the
sonotrode.
System pressure measurement:
Disables pressure indicator on the ADG display in
special machine configurations.
Travel measurement:
Disables travel indicator on the ADG display in
special machine configurations and selects various
travel scales.
Amplitude mode:
External control of the amplitude in special machi-
ne configurations.
6.3.2
6.3.2.1
Options 1