5 | Assembly and initial start-up
RINCO ULTRASONICS AG
64 / 137
BA_Standard3000_GB_V5.1_36566
Compressed air connections
Work on the pneumatic system may only be carried out by pneumatic
experts.
– Make sure that the compressed air is dry and oil-free
– Make sure that the input pressure is limited to 7 bar / 105 psi (if the
pressure is higher, air is released through a safety valve on the press!).
– Turn the manual check valve (21) at a right angle to the flow direction.
– Connect the air hose (21a) to the existing air circuit.
– Turn the manual check valve (21) to its operating position.
Jumper
For use in special machines, the operating mode "Automatic" can be set on
the jumper. For this operating mode, these operating instructions and the
declaration of conformity do not apply. Please contact our service depart-
ment if the ultrasonic welding machine is to be used in special machines.
WARNING
Bypassing safety devices and equipment.
Danger of severe injury!
• Do not change jumper settings. Always leave jumper in
"manual" mode.
When installing the welding machine in special machines, start-up (i.e.
starting operation as described) is prohibited until it has been proven that the
machine is in compliance with the directive 2006/42/EC (Machinery Directi-
ve) and the harmonised standard EN 60204-1.
5.4.2
Fig. 37:
Pneumatic system
5.4.3
Fig. 38:
Jumper