Error tables
In the following error tables, the error messages and possible causes of the
errors are listed.
NOTE
In the case of errors that are not caused by the application,
contact your nearest RINCO ULTRASONICS AG service
centre.
Generator error
S.:
No. Error message
Cause
Measures
002: 000 Maximum power loss
reached (Pv test)
Oscillator system loses too
much power in the "air"
▪ Clean interface surfaces
▪ Replace converter, booster or
sonotrode if necessary
002: 001 Mains voltage too low
The mains voltage for the
oscillator is too low.
▪ Check mains voltage, correct if
necessary.
▪ Replace generator module
002: 002 12 V power pack defective The 12 V power pack is
defective
▪ Check mains voltage
▪ Check fuses
▪ Replace generator module
002: 003 Minimum modulation output
stage
The minimum modulation of
the output stage below limit
▪ Check oscillator system, replace if
necessary
▪ Replace generator module
002: 004 Temperature of output
stage too high
The set maximum tempera-
ture value at the heat sink
of the power transistor has
been reached
▪ Check cooling
▪ Improve cooling of the generator
module
▪ Replace generator module
002: 005 Frequency below lower limit The frequency has dropped
below the lower limit
▪ Check oscillator system, replace if
necessary
▪ Check RF cable and replace if
necessary
002: 006 Maximum frequency
exceeded.
The frequency has excee-
ded the maximum limit
value
▪ Check oscillator system, replace if
necessary
002: 007 Maximum converter voltage
exceeded
The maximum converter
voltage has been exceeded
▪ Check oscillator system, replace if
necessary
▪ Replace generator module
002: 008 Output overload value
exceeded
The current power is larger
than the permissible set
limit value
▪ If the error occurs repeatedly, the
limit setting must be corrected
▪ Reduce contact pressure on
workpiece
▪ If the limit is set to the highest
level, the parameter setting must
be adjusted.
▪ If no better welding result can be
achieved with a lower pressure, a
more powerful generator must be
used
8.5