RIGOL
© Copyright
RIGOL
Technologies, Inc. 2007
User’s Guide for DG1000 Series
2-23
Table 2-13 Waveform Parameter Edition Menu
Function
Menu
Settings
Explanation
Point#
Select the point to be edited
Time
Set time for the Selected point
Voltage
Set Voltage for the Selected point
Insert
Insert a new point between the
defined points. Use the “Time” and
“Voltage” to define the new point.
Remove
Remove the current point
Save
Save the created waveform to the
non-Volatile Memory.
Instruction:
The time for the last definable point should be less than the cycle period in the
waveform.