192
6.15.3 Add to table
Input/output Operand
Data type
DATA
VW, IW, QW, MW, SW, SMW, LW, T, C, AIW, AC,constant, *VD, *LD, *AC integer
TBL
VW, IW, QW, MW, SW, SMW, LW, T, C, *VD, , *LD *AC
word
AD -T- TBL:
The instruction adds the word (DATA) to the
table (TBL).The first value in the table is the maximum
length of the table .The second value is the entry count
(EC),it specifies the number of entries in the table.Each
time you add new data to the table,the number of entries
adds 1.Table can contain up to 100 entries
,
not including
the first entry and the second entry.
error conditions:
0006 Indirect address
0091 Operand range
SM1.4 Table overflow
Special memory bit:
SM1.4 Table overflow
For example:
PLC program
:
Data block:
Summary of Contents for PR-12 Series
Page 26: ...19 1 xLogic CPU PR 12 Series CPU PR 14 and PR 18 series 1 PR 18 CPU 2 PR E extension...
Page 27: ...20 PR 24 series...
Page 47: ...40 5 3 Instruction tree...
Page 58: ...51 5 3 10 Instructions Instructions will be explained in detail in the instructions section...
Page 93: ...86 2 Enter the illegal real number Example...
Page 127: ...120 Example...
Page 139: ...132 Special memory bit SM1 0 Zero result SM1 1 overflow SM1 2 Negative result Example...
Page 149: ...142 Example...
Page 152: ...145 Example ATCH instruction only needs to be connected once...
Page 154: ...147 Example...
Page 175: ...168...
Page 217: ...210 Example Four arithmetic operation Main program...
Page 218: ...211 Subroutine...
Page 252: ...245 10 8 Example of serial port free port communication Program 1...
Page 254: ...247 10 9 Example of CAN free port...
Page 258: ...251 Conversion of Process quantity and set value unit...