183
6.14.2 Copy string
Input/output Operand
Data type
IN
VB, Constant string, LB, *VD, *LD, *AC
Character string
OUT
VB, *VD, LB, *LD, *AC
Character string
STR-CPY
:Instruction copies the
“
IN
”
string to the
“
OUT
”
string.
The longest constant string is 126 bytes.
error conditions:
0006 Indirect address
0091 Operand range
ASCII constant string data type format
:
String is a series of characters, each character is stored as a byte.The first byte of a
string defines the length of the string, that is the number of characters.If a constant
string is entered directly into the program editor or data block, the string must start
and end with double quotation marks ("string constant").
Example:
When M0.0 is 1,string starting with VB0 is copied to the string starting with
VB100 .VB100 storage is an integer 6
,
VB101 storage is character "1"
,
VB102 storage
is character "2"
,
VB103 storage is "3"
,
VB104 storage is "4"
,
VB105 storage is "5"
,
VB106 storage is "6".
Summary of Contents for PR-12 Series
Page 26: ...19 1 xLogic CPU PR 12 Series CPU PR 14 and PR 18 series 1 PR 18 CPU 2 PR E extension...
Page 27: ...20 PR 24 series...
Page 47: ...40 5 3 Instruction tree...
Page 58: ...51 5 3 10 Instructions Instructions will be explained in detail in the instructions section...
Page 93: ...86 2 Enter the illegal real number Example...
Page 127: ...120 Example...
Page 139: ...132 Special memory bit SM1 0 Zero result SM1 1 overflow SM1 2 Negative result Example...
Page 149: ...142 Example...
Page 152: ...145 Example ATCH instruction only needs to be connected once...
Page 154: ...147 Example...
Page 175: ...168...
Page 217: ...210 Example Four arithmetic operation Main program...
Page 218: ...211 Subroutine...
Page 252: ...245 10 8 Example of serial port free port communication Program 1...
Page 254: ...247 10 9 Example of CAN free port...
Page 258: ...251 Conversion of Process quantity and set value unit...