TROUBLESHOOTING
SeaBat 7125 SV2 Operator‟s Manual
Page 136
July 25, 2011
Version 3
A.5 Alarm Messages
– Master List in Alphabetical Order
Message
Description
Action
Alarm Type
2nd ADMXRC card not found
One or more of the processing cards
has failed to initialize or is non-
functional within the transceiver.
Reboot transceiver and try again.
PCI Card
ADMXRC card not found, ERROR =
One or more of the processing cards
has failed to initialize or is non-
functional within the transceiver.
Reboot transceiver and try again.
PCI Card
ADMXRC configuration failed
The software failed to detect or
configure the primary processing card.
Check PCI bus drivers for ADMXRC
card.
General System
Startup
ADMXRC.dll not found.
One or more of the processing cards
has failed to initialize or is non-
functional within the transceiver.
Reboot transceiver and try again.
PCI Card
Calibration Error: Calibration might be
invalid. Repeat the calibration.
Calibration has failed. Check BITE
page and hardware and cable
installation to the receiver.
Check environmental noise. Contact
RESON Customer Support.
Calibration
Calibration Failed: Magnitude Error
Calibration has failed. Check BITE
page and hardware and cable
installation to the receiver.
Check environmental noise. Contact
RESON Customer Support.
Calibration
Calibration Failed: Over 10% dead Rx
channels.
Calibration has failed. Check BITE
page and hardware and cable
installation to the receiver.
Check environmental noise. Contact
RESON Customer Support.
Calibration
Calibration Failed: Phase Error
Calibration has failed. Check BITE
page and hardware and cable
installation to the receiver.
Check environmental noise. Contact
RESON Customer Support.
Calibration
Calibration Failed: Too much noise
Calibration has failed. Check BITE
page and hardware and cable
installation to the receiver.
Check environmental noise. Contact
RESON Customer Support.
Calibration
Summary of Contents for SeaBat 7125 SV2
Page 2: ...This page intentionally left blank...
Page 211: ......