TROUBLESHOOTING
SeaBat 7125 SV2 Operator‟s Manual
Page 131
July 25, 2011
Version 3
A.3.3 Data Reading Alarms
Message
Description
Action
DMA Transfer Timeout. <x> of <x>
bytes received
This error generally indicates
that the uplink from the
receiver is interrupted at
some point.
Check the BITE tab for
receiver BITE values.
Restore factory defaults.
Reboot the PC.
FATAL: DMA Read size limitation
reached.
A general error occurred
while transferring data to the
software.
Reboot the system.
Lost sync with DMA read
A.3.4 System Resource Alarms
Message
Description
Action
Error starting I&Q Reader thread.
A module has failed to start
correctly.
Reboot the system.
Error starting IQ thread.
Error starting PCI Copier thread.
Error starting PCI Reader thread
Error creating IQ thread
Error starting I&Q threads
A.3.5 Input Signal (Timing and Triggers) Alarms
Message
Description
Action
Failed to register external trigger,
ERROR =
The pulse is not being
detected. Time stamping will
be done using system time
only. 1 millisecond accuracy
not possible.
Check input signal
cabling.
Failed to unregister external trigger,
ERROR =
FIRMWARE does not support
External Trigger. Pinging is OFF
External triggering has failed.
Check/update software installation.
FATAL ERROR: PPS Timestamp
error Check 1 PPS input
A.3.6 Calibration Alarms
Message
Description
Action
Calibration Failed: Too much noise
Calibration has failed. Check
BITE page and hardware and
cable installation to the
receiver.
Check environmental
noise. Contact RESON
Customer Support.
Calibration Failed: Over 10% dead
Rx channels.
Calibration Failed: Magnitude Error
Summary of Contents for SeaBat 7125 SV2