D2
Filter hub N for transmitted-light
⬤
(Red dot)…….......……………………… Empty opening
⬤
….………….………………………………. Neutral density filters 32x2 N3, T=12.5%
⬤
….………….……………………………… Neutral density filters 32x2 N6, T=1.6%
⬤
….………….………………………………. Neutral density filters 32x2 N9, T=0.2%
⬤ ….………….……………………………… Neutral density filters 32x2 N12, T=0.025%
⨂ ….………….……………………………….. Cover plate
Filter holder CF for contrast fluorescence
⬤
(Red dot)………………………………….. Empty opening
◯
(red)..…..………………………………….. Red filter 50x3 RG 610/h
◯ (black)….………………………………….. Neutral density filter 50x2 N6, T=1.6%
Filter hub U for transmitted-light
U1 (yellow)……………............................ Exciter filter for UV brightfield 50x(2.5 BG 38/h + 3 UG 1/h)
U2 (white)…...………............….............. Exciter filter for UV darkfield 50x1.5 UG 1/h
U3 (yellow)………….........................…… Exciter filter for simultaneous contrast fluorescence 50x (2 BG 12/h + 1.5 UG 1/h)
O (white)……………………………………… IR- and UV-blocking filter 50x (4 KG 3/h + 2 GG 395 + 1.5 FG 2)
S (black)………………………………………. IR-blocking filter 50x 1.7 KG 1/h
O………………………………………………... Cover plate
Filter hub S for transmitted-light
⬤
(Red dot)………………….…………..….. Empty opening
◯
(blue)……………………………….......... Conversion filter for halogen lamp, 3200° to 6000°K, 32x2 KB 12
◯
(green)……………………………..…...... Green filter for phase contrast and photo, 32x2 VG 14/h
For conventional blue fluorescence (e.g., with quinacrine)
S1 (blue)……......................................… Exciter filter for blue brightfield 32x3 BG 12/h, 2 Pcs.
S2 (white)….............................. Neutral density filters for comparison observation with visible light, 32x2 N 6, T=1.6%
S3 (blue)…......................................…… Exciter filter for blue darkfield, 32x3 BG 12/h
For immunofluorescence (only with darkfield condenser)
S1 (blue)……….………………………........ Exciter filter for FITC, broadband, 32x(2.5 FITC 490 + 2 GG 395)
S2 (blue)……….…………………………….. Exciter filter for FITC, narrowband, 32x3, 5 FITC-N
S3 (green)………..………………………….. Exciter filter for rhodamine, narrowband, green, 32x4 (λ=546nm)
For catecholamines (only with darkfield condenser)
S1 (white)……….…………..………...…..... Exciter filter for UV for dopamine detection, 32x1.5 UG 1/h
S2 (yellow)……….….…………................. Exciter filter for catecholamines, broadband, 32x2 CAT 425
S3 (white)……….………..………………..... Exciter filter for catecholamines, narrowband, 32x5 (λ = 405nm)
Blocking-filter slide in the transmitted-light optics carrier
O (yellow)..…….…………………………………........ UV blocking filters 25x3 KV 450/VG
OO (red, white)..…………………………………....... UV blocking filters 25x3 KV 418/VG
O (blue)………...…………………………….......……. Blue blocking filter 25x3 (GG9 + OG 515/VG
O (green)……….…………………………….......……. Blue blocking filter 25x3 (GG9 + OG 530/VG. For immunofluorescence for
observation of rhodamine, the green blocking filter 25x3 OG 590/VG is used. It is combined with filter S3.
Summary of Contents for Univar
Page 1: ...Reichert Univar Manual...
Page 2: ......
Page 48: ...D6 blank no content...
Page 58: ...E2 blank no content...