background image

C3

Conventional fluorescence and quinacrine with
epifluorescence
With the epifluorescence illuminator, you can
simultaneously perform all illumination methods
using the interference beamsplitter mirror 40. For
isolation of paler details we recommend transmitted-
light phase contrast (page C9) or transmitted-light
darkfield (page C7) to sharpen the specimen image

Conventional fluorescence and quinacrine:
⚪  Turn on the HBO 200W mercury-vapor pressure
lamp
⚪  Turn off the transmitted-light halogen lamp
⚪  Turn off the neutral density filters in the body
(black dot)
⚪  Turn on relay (red dot). For weak fluorescent
objects, it can be switched off
⚪  Turn off the Bertrand lens
⚪  Turn off the main IC prism and analyzer

⚫  Put on the UV-blocking orange shade

⚫  Rotate into place the 10x objective

⚫  Slide the interference mirror switch to 40 or 49,
depending on the desired excitation (page C4)

⚪  Set the photo system magnification changer to
low magnification (red dot, L)
⚪  Direct beam path to the camera (red dot, CAM)
⚪  Set beam to the body to 20% (red dot,CAM/PRO)
⚪  For weak fluorescent preparations, set to EYE
⚪  Switch off the phase ring knob (red dot)
⚪  Set the relay magnification changer to 1x (red
dot)
⚫  Set the swivel mirror to high-performance lamp
⚫  Set the rotary prism to high-performance lamp
⚪  Sharpen with coarse and fine focus on the
fluorescent image
⚫  Adjust the high-performance light collector to
evenly illuminate the field
⚪  Adjust the field iris diaphragm opening in the
epifluorescence illumination pipe (page C4) with the
knurled wheel; to focus the iris image, loosen the
hex pin and move axially. Tighten the pin and open
the field iris diaphragm

NOTE:
The filters in the epifluorescence attachment have a
colored label for each fluorescence method. These
fluorescence methods can also be done with
transmitted-light exciter using the corresponding
transmission exciter filter with the same color, on
the mirror house 2 or 4

Summary of Contents for Univar

Page 1: ...Reichert Univar Manual...

Page 2: ......

Page 3: ...Translated from the 11 1975 German language edition with slight modifications William R Porter San Marcos CA USA 2017 v 1 4...

Page 4: ...nuals or literature were used nor indeed available in the production of this one This manual was translated purely for the use of myself it is being made available to the public free of charge for the...

Page 5: ...rescence C5 Mixed illumination epifluorescence transmitted light darkfield epifluorescence transmitted light darkfield fluorescence C7 Mixed illumination epifluorescence transmitted light phase and an...

Page 6: ...ral notes Observation tube F1 Rotating stage No 28 F1 Coarse drive stop F1 Condenser coarse and fine adjustments F1 Transmitted light objectives F2 Wide field plan compensation eyepieces F2 Relay syst...

Page 7: ...ses is ensured for proper air circulation Remove the protective transport pieces The necessary hex wrench to unscrew the pieces is included a Remove the red plate covering the projection prism by unsc...

Page 8: ...ith the condenser coarse feed to the lower stop position Hang the condenser turret transverse pin into the v shaped notch on top of the stand s condenser mount by tilting it back slightly hanging by t...

Page 9: ...used for working with the XBO 450W Xenon lamp for the HBO 200W mercury vapor pressure lamp use filter holder H Replace the back panel of the mirror housing on the orientation pin located above and sec...

Page 10: ...hree carrying handles can be unscrewed from the base of the microscope stand The threaded holes are provided with screw plugs Hand pads The magnetic hand rests are pushed on to the stand Eyepieces The...

Page 11: ...ust collector for transmitted light halogen lamp set red dot Adjust the photo system magnification changer to low magnification L red dot Set the beam path to the camera red dot CAM Set the beam to 20...

Page 12: ...0 90 Free working distance 0 29mm Use for all lenses from 4x to 100x When working with the 4x objective the condenser turret is set on 4 Recommended for all investigation methods where the immersion c...

Page 13: ...light halogen lamp red dot Set the magnification lever in the photo system to low magnification red dot L Redirect the beam path to the camera red dot CAM Set eyepiece light to 20 red dot CAM pro Set...

Page 14: ...rformance lamp Engage the neutral density filters for transmitted light when needed Evenly illuminate the field with the high performance lamp collector Immersion darkfield condenser N A 1 18 1 42 oil...

Page 15: ...Switch off supplementary optics for widefield condenser red dot Adjust the transmitted light halogen lamp collector for even illumination red dot Set the photo magnification changer to L red dot Redir...

Page 16: ...er lenses are also marked with the objective magnification The position 0 of the knob the red dot position provides an empty hole in the beam path Phase ring selection The phase annuli annular diaphra...

Page 17: ...h off the auxiliary optics for wide field condenser red dot Set the photo system magnification changer to low magnification red dot L Direct beam path to the camera red dot CAM Set beam at 20 to the b...

Page 18: ...r scale indicates degrees by 1 10 The polarization direction is north south at the 0 position A readjustment of the analyzer can be carried out as follows move the polarizer into place Hold the measur...

Page 19: ...arse feed to the stop Switch off the auxiliary optics for wide field condenser red dot Adjust collector for halogen lamp red dot Adjust the photo system magnification changer to low magnification red...

Page 20: ...rast main prism is inserted into the opening just above the front of the objective nosepiece and secured with the knurled screw at the side of the nosepiece To remove loosen the knurled screw and with...

Page 21: ...er filter for transmitted light red dot Switch off the neutral density filters for transmitted light red dot Switch off the auxiliary optics for wide field condenser red dot Adjust the photo magnifica...

Page 22: ...light with 4x objective use the frosted 4 filter on the lower condenser turret Blocking filter slide for fluorescence The blocking filter slide is inserted into the transmitted light optics carrier T...

Page 23: ...slide and the immersion condenser Put UV shade tube on light well Set the collector of the high performance light on the mark Switch off the auxiliary optics for wide field condenser red dot Set off e...

Page 24: ...ght fluorescence The blocking filter slide is inserted into the transmitted light optics carrier The empty slide is removed by pulling on the spring retainer at the front of the optics cavity The colo...

Page 25: ...light halogen lamp red dot Set the photo magnification changer to red dot Direct the beam path to the camera red dot CAM Direct 20 beam to the body red dot CAM PRO For weak fluorescent objects select...

Page 26: ...rings for other objectives are also marked with the objective magnification In the knob position 0 red dot the beam path is empty Ring aperture for contrast fluorescence There are specially designed...

Page 27: ...ht blocking tube on light well Switch off exciter or color filter for transmitted light red dot Switch off neutral density filters for transmitted light red dot Adjust the halogen lamp transmitted lig...

Page 28: ...for fluorescence studies Blocking filter slide for transmitted light fluorescence The blocking filter slide is inserted from the right in the transmitted light optics carrier The spring retainer on t...

Page 29: ...desired excitation page C2 Adjust the photo magnification changer to low red dot L Direct beam path to the camera red dot CAM Direct 20 beam to the body red dot CAM PRO With weak fluorescent preparati...

Page 30: ...ed size for microphotometry These apertures are used when measuring the smallest object details and are centered and focusable Filter Number Exciter Filter Interference Mirror Blocking Filter Use 40 w...

Page 31: ...excitation page C4 Set the photo system magnification changer to low magnification red dot L Direct beam path to the camera red dot CAM Set beam to the body to 20 red dot CAM PRO For weak fluorescent...

Page 32: ...ting up to approx 450nm 18x3 GG 9 G2 GG 9 VG By default no function The built in filters are intended for future expansion 49 Blue Blue exciter filter 18x3 BG 12 Blue reflective until approx 490nm 18x...

Page 33: ...C6 Set the photo system magnification changer to low magnification red dot L Direct beam path to the camera red dot CAM Set beam to 20 red dot CAM PRO For weak fluorescent preparations set to to EYE...

Page 34: ...usted at the same time with the help of the sliding lever located on the front of the attachment The number designation is derived from the long wavelength end of the reflection band of the individual...

Page 35: ...to the stop A uniform liquid contact should occur between the immersion darkfield condenser and the specimen slide Turn the lower condenser turret to the empty opening red dot Rotate off the auxiliary...

Page 36: ...the iris assembly towards or away from the operator C mixed light epifluorescence transmitted light darkfield Set up initially as in A for transmitted light darkfield with halogen lamp Then adjust as...

Page 37: ...s for wide field condenser red dot Set collector for transmitted light halogen lamp red dot Adjust the photo system magnification changer to low magnification red dot L Direct the beam path to the cam...

Page 38: ...iris diaphragm in the epifluorescence light pipe with the knurled ring and focus your image after loosening the hex shaft and moving forward or backward C mixed light Turn on the halogen lamp so that...

Page 39: ...s for wide field condenser red dot Set collector for transmitted light halogen lamp red dot Adjust the relay magnification to low red dot L Direct beam path to the camera red dot CAM Set ocular light...

Page 40: ...image and the transmitted light interference contrast image can be seen at the same time To better distinguish between of the two images you can rotate in a contrast filter for the halogen lamp Interf...

Page 41: ...the photo magnification changer to low red dot L Direct light path to the camera red dot CAM Direct 20 beam to the ocular tube red dot CAM PRO Turn the phase ring knob to off red dot Set magnification...

Page 42: ...Adjust the field iris diaphragm in the epifluorescence light pipe using the knurled ring and sharpen the iris image in the image plane by loosening hex post and sliding fore and aft C Mixed illuminati...

Page 43: ...25 and on the right lamp house 50 The mirror knobs allow by simply switching a alternating the lighting between transmitted or epi illumination b mixing lighting from transmitted or epi illumination...

Page 44: ...ional blue fluorescence e g with quinacrine S1 blue Exciter filter for blue brightfield 32x3 BG 12 h 2 Pcs S2 white Neutral density filters for comparison observation with visible light 32x2 N 6 T 1 6...

Page 45: ...25 or 50 on the right This allows a alternative transmitted or epi illumination b mixed transmitted and epi illumination Use and combination of the exciter and blocking filter The exciter and blocking...

Page 46: ...tfield is to be placed on the UV light shield tube 50x3 BG 12 h For immunofluorescence only with darkfield condenser S1 blue Exciter filter for FITC wideband 32x 2 5 FITC 490 2 GG 395 S2 blue Exciter...

Page 47: ...lace a specimen on the stage After switching on the low voltage halogen lamp adjust for transmitted light brightfield microscopy Swivel the ground glass to off Turn the collector of the halogen lamp I...

Page 48: ...D6 blank no content...

Page 49: ...rprints on the quartz body will burn For reasons of operational safety change the lamp when the average lifespan is reached please observe the instruction manual for the lamp With the coin screw open...

Page 50: ...he collector knob of the high performance lamp counterclockwise until it stops Redirect the microscopic optical path to view the lamp arc on the projection screen This is done through height adjustmen...

Page 51: ...anged then the lamp may fail to ignite since the cables may short out to the metal housing Installation of the mercury vapor high pressure lamp HBO 200W 2 PLEASE NOTE Before opening the lamp house unp...

Page 52: ...stage set the Univar to transmitted light brightfield with the high performance lamp for the light source Swivel ground glass off Turn off automatic zoom lighting and adjust the zoom handwheel to 63...

Page 53: ...ves the 6V or 12V low voltage lamps It must be connected only to alternating current The primary voltage range is set by 100 125V or 200 250V in the factory The line cord into the power supply supplie...

Page 54: ...of the ignition device The red button must be pushed in again reset before again turning on with the switch It is also advisable to take a break before re igniting so that the lamp can cool down The b...

Page 55: ...ding to the modified power supply voltage and replace the button into the voltage selector The fuse to be used for line voltage of 110 125V is 10A for 150V is 6 3A and for 200 240V is 4A The main swit...

Page 56: ...the lamphouse 50 comes on Then the lamp is lit with the red start button on the lamphouse 50 See instructions on page D10 The current controller is set at the factory for 25A and should not be adjust...

Page 57: ...E1 E Trimatic Camera System Automatic camera 35mm 24 x 36mm format Camera with 4 x5 International film back Camera with Polaroid film cassette 3 1 4 x 4 1 4...

Page 58: ...E2 blank no content...

Page 59: ...via a cable that has two identical plugs One plug goes into the socket on the back of the microscope the second plug is connected to the back of the control unit The connectors will only connect in t...

Page 60: ...mally set to 220V When switching to a different voltage the inner head of the voltage selector is pushed in and removed after a quarter turn of the screw counterclockwise With a coin or screwdriver bl...

Page 61: ...l film and 70mm film This position is kept free for a not yet specified camera format The eyepiece mounts are adjusted by turning so that the lines of the double circle appear separated and as sharp a...

Page 62: ...rned to the left CCW If the pointer is in the left red field then the exposure time is too short you must turn to the right CW The bandwidth of the green field is 3 DIN In the case of very dark specim...

Page 63: ...rt and an exposure adjustment is no longer possible Press the fluor key and the pointer will move to the right so that you can balance up to 8 hours During the measurement of the long exposure times t...

Page 64: ...shutter to trigger any exposure time The shutter white indicator light remains open until the button is released again Interruption of exposure The stop button is used to interrupt an ongoing exposure...

Page 65: ...up to the shortest of 1 125 sec The operation is described in a separate manual Brightness dependent voltage According to the brightness of the microscopic image the output voltage range is 0 5V for...

Page 66: ...olaroid Roll Film Cassette 3 1 4 x 4 1 4 or the Roll Film Cassette Super Rollex 56 x 72mm can only be installed after removing the spring back The two springy levers which are located on the removable...

Page 67: ...nserted into the empty side of the cartridge chamber The beginning of the film is pushed into the slot of the take up spool until the teeth get hooked on the second perforation hole Now turn the take...

Page 68: ...r of images set on the external counter must not allow more exposures than the cassette counter so that the film transport is not disturbed If necessary set to an exposure less After all exposures are...

Page 69: ...oosening the fastening screw of the specimen slide positioner it can be removed from the stage table Coarse drive stop The adjustable coarse focus drive stop limits the height setting of the stage tab...

Page 70: ...nings Plan Plan achromatic lens Plan Apo Plan apochromatic objective lens Oil Glyz for oil or glycerin immersion Iris built in iris diaphragm 100x 1 25 objective magnification 100x numerical aperture...

Page 71: ...of the image are fully preserved The zoom system is especially useful for format filling photomicrography for an ideal adaptation to the specimen size Slider slot An opening in which you can insert a...

Page 72: ...her with the lighting setup this system achieves automatic K hler illumination The light coming from the lamp is optimally utilized and the conductance i e the product of the field and aperture is hel...

Page 73: ...if absolutely necessary use pure xylene The often still lingering coating can be removed with a piece of polystyrene foam However the previously used solvents must have evaporated completely It is pre...

Reviews: