NautoPilot® 5000 Series
102-890.NG001-NG003
Operator Manual
Edition: 003
69
10000001052
Function
Figure 33/17 Softkey for switching an alarm ON or OFF if the acceleration
overshoots an adjusted acceleration limit value (percentage
value).
Possible settings are:
- Off (no alert)
- On (an alert is activated if the limit is reached or
exceeded). Accel. Monitor is displayed in the status bar
at the top of the display.
Figure 33/18 Softkey for adjusting speed.
Adjusted value influences the Acceleration Limit (indication at
the top of this display).
Value range: 0.0 kn to 90.0 kn (in increments of 1 kn).
Figure 33/19 Softkey for adjusting the Rate of Turn (in degrees) in
combination with the speed.
Adjusted value influences the Acceleration Limit (indication at
the top of this display).
Value range: 5
/min to 500
/min (in increments of 1
/min.)
Figure 33/20 Softkey for adjusting the acceleration limit. This adjustment in-
fluences the Rate of Turn in the display below.
Value range: 0.000 m/s
2
to 9.999 m/s
2
(in increments of 0.001
m/s
2
).
Please note:
Critical values are displayed with a small attention
icon. These values must be checked and
corrected.
Figure 35:
Example of a request to press ”SET” after a
parameter has been changed