NautoPilot® 5000 Series
102-890.NG001-NG003
Operator Manual
10000001052
56
Edition: 003
2.3.3
Switching and Adjusting Rad/RoT
Figure 26: First Display (heading changes with RoT is selected).
Heading changes can be performed with a Rate of Turn (RoT) limit or with a
limited radius.
The respective mode can be selected with the Rad/RoT softkey. The currently
selected mode is displayed (Figure 25, Pos. 1).
Use the - and +softkeys (Figure 25, Pos. 2 and 4) to set the value RoT or the
value of the radius.
Each change of value must be acknowledged by pressing the SET button, at which
point a small icon is displayed communicating that this change must be
acknowledged. Hold the - or +softkey to perform a faster change of value
It is not possible to set one of the values to zero.
Value range for RoT: 005
/min to 500
/min (in increments of 1
/min).
Value range for Rad :0.1 NM (nautical mile) to 5.0 NM (in increments of 0.1 NM).
Note
: