NautoPilot® 5000 Series
102-890.NG001-NG003
Operator Manual
Edition: 003
153
10000001052
Alarms and warnings are displayed alphanumerical in the red or yellowish orange
top bar of the display (see Figure 63). The icon of the alert flashes until the ACK
button is pressed (acknowledgement).
Alarms, warnings or cautions are displayed together with an alert icon (see section
7.1)
NautoPilot® 5000 is not able to silence alerts. Silencing is only possible with CAM.
When an alert occurs for the first time, it is displayed with the long text.
After acknowledgement, the first line of the short message is displayed.
After the cause for a message is eliminated, the message is no longer displayed.
Additional information about the cause of an alert (example: Track Control Interrupted
- No Position) at the top bar of the display toggles between both text lines.
The NautoPilot® 5000 supports the responsibility take over functionality as defined in
IEC 62923-1.
The display of incoming alerts is delayed by 4 seconds in order to allow responsibility
transfer before activating optical and acoustical signals.
The NautoPilot® 5000 accepts responsibility transfer from external systems using the
alert communication as defined in IEC 62923-1 for category B alerts. The
responsibility of category A alerts cannot be transferred to external systems.
The NautoPilot® 5000 itself does not request responsibility from external systems.
Table 44
Alarms/messages alerts
Color
Meaning - visual
Acoustic signals
Red
(Alarm) flashing
Alarms (faults and/or
dangerous situations)
3 short signals (pulses), every
7 seconds. Continues until
acknowledgement.
yellowish orange
(Warning) flashing
Warnings
2 short signals (pulses) after the
event without repetition.
yellow (Caution)
Status messages
Information
There is no acoustic signal for
status and global messages.
Please note:
In order to avoid unintended acknowledgement of a
new incoming alert, the push button ACK is deactivated
for 1 second after receiving a new alert.