NautoPilot® 5000 Series
102-890.NG001-NG003
Operator Manual
10000001052
158
Edition: 003
Alarms can be:
- Power Failure
- No Heading
- Simulated sensor data
- Missing n APIFs
- Too many APIFs on the CAN bus, please check configuration
- The Autopilot has performed an automatic Reset
The first action to take when one of the above alarms has been activated should be
to reset the NautoPilot® Operator Unit either by switching OFF the supply voltage
or by re- moving the fuse at the rear.
7.3.2.1
Specials on Heading Failure
When the heading returns after a heading failure, the last Set Heading will be
suggested as new Set Heading and the Set LED flashes. Heading controller is set
off work and rudder will remain at actual rudder angle until either a new Set
Heading is selected and acknowledged (press Set button) or the steering mode is
changed.
An alert is displayed at the top bar of the display (see section 6).
Set
CHECK SET HEADING
Select a new Set Heading
3 pulses
repeated
every 7 seconds
Set
Only after the heading value is checked or changed and the button Set is pressed, it
is possible to acknowledge this alarm.
Set
Acknowledge the alert.