configuration is available on the OM20 GUI. Refer to Table 5.3 for the Remote/Terminal
connector pinout; and
Section
6 for the port interface specification.
The OM20’s internal M&C system is connected to most of the circuitry on any board contained
in the chassis. These connections provide status on the condition of the circuitry and provide the
data required for the various measurements the OM20 provides. The on-board M&C processes
this information and generates status indications and alarms when necessary. Detailed status
information is available via the GUI, Remote port, and the Form-C fault connections available on
this connector. This summary information can be connected to external equipment, switches, or
alarms. Refer to Table 5.3 for the Form-C connector pin-outs.
Table 5.3. Remote/Terminal/Fault Connector (J2)
Pin No.
Signal Name
Signal
Direction
A
Receive Data RS-232
RXD-232
Input
B
Transmit Data RS-232
TXD-232
Output
C
AGC Voltage
---
---
D
Transmit Data RS-485 (+)
TX-485-B
Output
E
Transmit Data RS-485 (-)
TX-485-A
Output
F
Receive Data RS-485 (+)
RX-485-B
Input
G
Receive Data RS-485 (-)
RX-485-A
Input
H
Ground
GND
---
J
Mod Fault – C
MF-C
---
K
Mod Fault – NC
MF-NC
---
L
Mod Fault – NO
MF-NO
---
M
Demod Fault
DF-C
---
N
Demod Fault – NC
DF-NC
---
S
Demod Fault – NO
DF-NC
---
R
Ground
GND
---
U
Default
---
---
P
Default
---
---
Summary of Contents for OM20
Page 2: ......
Page 4: ...This page is intentionally blank ...
Page 20: ...OM20 Universal Outdoor Modem Introduction MN OM20 Revision 5 1 4 Notes ...
Page 32: ...OM20 Universal Outdoor Modem Installation MN OM20 Revision 5 2 12 Notes ...
Page 38: ...OM20 Universal Outdoor Modem OM20 Initial Configuration MN OM20 Revision 5 3 6 Notes ...
Page 66: ...OM20 Universal Outdoor Modem OM20 Theory of Operation MN OM20 Revision 5 4 28 Notes ...
Page 138: ...OM20 Universal Outdoor Modem Web Browser Remote Protocol MN OM20 Revision 5 6 64 ...
Page 164: ...OM20 Universal Outdoor Modem Technical Specifications MN OM20 Revision 5 8 20 Notes ...
Page 198: ...OM20 Universal Outdoor Modem Appendix E MN OM20 Revision 5 E 16 Notes ...
Page 204: ...OM20 Universal Outdoor Modem Appendix F MN OM20 Revision 5 F 6 Notes ...
Page 214: ...OM20 Universal Outdoor Modem Appendix G MN OM20 Revision 5 G 10 Notes ...
Page 218: ...OM20 Universal Outdoor Modem Appendix G MN OM20 Revision 5 H 4 Notes ...
Page 220: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX ...