OM20 Universal Outdoor Modem
OM20 Theory of Operation
MN-OM20– Revision 5
4–7
4.3.1
Terminal Port
This port supports an asynchronous control protocol as described in Section 4. It is configured to
support RS-232 signal levels. This port is intended for use in computer-based remote M&C. All
functions of the modem may be monitored and controlled from this port via a common terminal
connected to the Terminal Port. This function is front panel selectable.
The Terminal Mode Control allows the use of an external terminal or computer to monitor and
control the modem from a full screen interactive presentation operated by the modem itself. No
external software is required other than VT-100 Terminal Emulation Software (e.g. “Procomm”
for a computer when used as a terminal. The Control Port is normally used as an RS–232
Connection to the terminal device. The RS-232 operating parameters can be set using the modem
Front Panel and stored in Non-volatile memory for future use.
Refer to the Remote Protocol Manual (TM117) for the Terminal, Remote and
SNMP screens and protocols.
4.3.2
Modem Remote Communications (RLLP)
The Remote Port located on J20 allows for control and monitoring of parameters and functions
via an RS-232 Serial Interface, or RS-485 for RLLP Protocol. ‘Equipment Remote Mode’ setup
can be entered from the front panel or the Web Browser interface under the “System” menu. This
requires the user to first set the Remote Port Control to “Remote” then set the Multidrop Address
as needed followed by setting the Remote Interface to RS232 or RS485.
Control and status messages are conveyed between the modem and all subsidiary modems and the
host computer using packetized message blocks in accordance with a proprietary communications
specification. This communication is handled by the Radyne Link Level Protocol (RLLP), which
serves as a protocol ‘wrapper’ for the RM&C data. Complete information on monitor and control
software is contained in the following sections.
4.3.3
Ethernet M&C Port
This port is dedicated for Ethernet Communications supporting SNMP, FTP and Web Browser.
The port is configured for 10 Base-T communications protocols. The Ethernet M&C Interface
requires a standard RJ45 Male connector. Refer to Appendix E and F for proper setup of the
TCP-IP interface and Web Browser Setup.
Summary of Contents for OM20
Page 2: ......
Page 4: ...This page is intentionally blank ...
Page 20: ...OM20 Universal Outdoor Modem Introduction MN OM20 Revision 5 1 4 Notes ...
Page 32: ...OM20 Universal Outdoor Modem Installation MN OM20 Revision 5 2 12 Notes ...
Page 38: ...OM20 Universal Outdoor Modem OM20 Initial Configuration MN OM20 Revision 5 3 6 Notes ...
Page 66: ...OM20 Universal Outdoor Modem OM20 Theory of Operation MN OM20 Revision 5 4 28 Notes ...
Page 138: ...OM20 Universal Outdoor Modem Web Browser Remote Protocol MN OM20 Revision 5 6 64 ...
Page 164: ...OM20 Universal Outdoor Modem Technical Specifications MN OM20 Revision 5 8 20 Notes ...
Page 198: ...OM20 Universal Outdoor Modem Appendix E MN OM20 Revision 5 E 16 Notes ...
Page 204: ...OM20 Universal Outdoor Modem Appendix F MN OM20 Revision 5 F 6 Notes ...
Page 214: ...OM20 Universal Outdoor Modem Appendix G MN OM20 Revision 5 G 10 Notes ...
Page 218: ...OM20 Universal Outdoor Modem Appendix G MN OM20 Revision 5 H 4 Notes ...
Page 220: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX ...