OM20 Universal Outdoor Modem
OM20 Theory of Operation
MN-OM20– Revision 5
4–18
4.11
OM20 Automatic Uplink Power Control (AUPC Operation)
Refer to Appendix F
4.12
Asynchronous Overhead Operation J3 (Framing/Multiplexer Capability)
The Asynchronous Framing/Multiplexer is capable of multiplexing a relatively low-speed
overhead channel onto the terrestrial data stream resulting in a slightly higher combined or
aggregate data rate through the modem. The overhead channel is recovered at the far end. This
added channel is termed variously “An Overhead Channel”, ”Service Channel”, “Async Channel”
or in IESS terminology an “ES to ES Data Channel.” The basic frame structure used by the
multiplexer is that specified in the IESS-309 Standard, resulting in a 16/15 Aggregate ratio of
overhead & data to data rates.
For Regular Async:
(Standard IBS), the Baud Rate is approximately 1/2000 of the
Data Rate listed in Table 4-2.
For Enhanced Async:
(IBS Async.), the Baud Rate is selectable, but Data Rate is
limited.
The maximum Baud Rate is 19,200 bps for IBS Async. Two software-controlled modes are
designed into the card to best utilize the available bits; “Standard IBS” and “IBS (Async)”. The
characteristics of the Channel Interface are also determined by the standard or Async mode.
The Async Channel can be set under software-control to either RS-232 or RS-485 mode. The pin
assignments for both modes are shown in Table 4-2.
The “RS-485” Setting controls the output into tri-state when the modem is not transmitting data,
allowing multiple modem outputs to be connected together.
Table 4-2.
Kbps
Baud Rate Example for
Standard IBS
Kbps
Baud Rate Example for
Enhanced Mode
128
64
9.6
300
256
128
19.2
600
384
192
32
600
512
256
64
1200
640
320
128
2400
768
384
192
4800
896
448
256
4800
1024
512
320
9600
1152
576
384
9600
1280
640
448
9600
1408
704
512
9600
Summary of Contents for OM20
Page 2: ......
Page 4: ...This page is intentionally blank ...
Page 20: ...OM20 Universal Outdoor Modem Introduction MN OM20 Revision 5 1 4 Notes ...
Page 32: ...OM20 Universal Outdoor Modem Installation MN OM20 Revision 5 2 12 Notes ...
Page 38: ...OM20 Universal Outdoor Modem OM20 Initial Configuration MN OM20 Revision 5 3 6 Notes ...
Page 66: ...OM20 Universal Outdoor Modem OM20 Theory of Operation MN OM20 Revision 5 4 28 Notes ...
Page 138: ...OM20 Universal Outdoor Modem Web Browser Remote Protocol MN OM20 Revision 5 6 64 ...
Page 164: ...OM20 Universal Outdoor Modem Technical Specifications MN OM20 Revision 5 8 20 Notes ...
Page 198: ...OM20 Universal Outdoor Modem Appendix E MN OM20 Revision 5 E 16 Notes ...
Page 204: ...OM20 Universal Outdoor Modem Appendix F MN OM20 Revision 5 F 6 Notes ...
Page 214: ...OM20 Universal Outdoor Modem Appendix G MN OM20 Revision 5 G 10 Notes ...
Page 218: ...OM20 Universal Outdoor Modem Appendix G MN OM20 Revision 5 H 4 Notes ...
Page 220: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX ...