Chapter 3 - Setup and Installation
SES Controller Card Switch Setting Overview
57
Refer to this chart to see how the ID range is assigned.
Device ID Ranges
Drive Slots and Sample IDs Assigned
NOTE:
Odd numbered drive slots are assigned to Channel 0 and even numbered
drive slots are assigned to Channel 1 of the RAID Controller. This allows
for improved performance throughput.
The table below provides the drive spin up options.
“DL” Switch 7
“RM” Switch 8
Drive Spin-up Mode
Down *
Down *
Drive motor spins up at DC power on.
Down
Up
Drive motor spins up only on device “start” commands.
Up
Down
Drive motor spins up after a delay of 12 (may vary
depending on drive type) seconds times the numeric device
ID setting of the associated drive.
Up
Up
Drive motor will not spin-up.
* Default setting for proper operation.